330180-12-00
Description
I. Model Explanation (330180-12-00)
330180: 3300 XL 8mm Eddy Current Preamplifier (General Model) twelve
1: Total system length: 1m (probe + cable)
2: No installation hardware (bare machine, without panel / DIN base)
00: No explosion-proof certification (for ordinary industrial environment)
II. Electrical parameters (standard 3300 XL)
Power supply: -17.5 ~ -26 VDC
Current: ≤ 12 mA
Sensitivity: 7.87 mV/μm (200 mV/mil)
Linear range: 0.25 ~ 2.3 mm; recommended gap 1.27 mm (-9 VDC)
Frequency response: 0 ~ 10 kHz
Output impedance: 50 Ω
III. Mechanical and environmental
Dimensions (H×W×D): 63.5 × 61 × 81.3 mm
Weight: Approximately 0.32 kg
Shell: A308 aluminum alloy, IP54
Temperature: -40°C ~ +85°C
Certification: CE, RoHS, SIL2/3 (without ATEX/IECEx/CSA explosion-proof)
IV. 1m system kit
Probe: 330191-00-26-01-00 (8mm, 1m integrated cable, non-explosion-proof)
Extension cable: Not required (1m integrated)
Monitor: 3500/40 (vibration), 3500/42 (axial position)
V. Terminal blocks (bare machine)
-24 VDC (power negative)
COM (common terminal)
OUT (signal output)
SHIELD (shielding layer)
VI. Difference from 330180-12-05
330180-12-00: 1m, no installation parts, non-explosion-proof
330180-12-05: 1m, no installation parts, explosion-proof (ATEX/IECEx/CSA)
VII. Installation tips
Additional purchase required: Panel base 330180-01 or DIN rail base 330180-02
Gap setting: 1.27 mm (-9 VDC)
Cable: Curvature radius ≥ 25mm,严禁 cutting; Shielding layer single end grounding at cabinet end
Get a Quote