330180-50-05
Description
I. Model Meaning
330180: 3300 XL 8mm Eddy Current Preprocessor 50
5: Total system length 5m (probe + cable)
0: Panel installation (different from DIN rail 51)
05: CSA/ATEX/IECEx explosion-proof certification (Ex ia IIC T5)
II. Electrical parameters
Power supply: -17.5 ~ -26 VDC (without safety barrier); -23 ~ -26 VDC (with safety barrier)
Current: ≤12 mA
Sensitivity: 7.87 mV/μm (200 mV/mil)
Linear range: 0.25 ~ 2.3 mm; recommended gap 1.27 mm (-9 VDC)
Frequency response: 0 ~ 10 kHz
Output impedance: 50 Ω
III. Mechanical and environmental
Size (H×W×D): 63.5 × 61 × 81.3 mm
Weight: approximately 0.32 kg
Shell: A308 aluminum alloy, IP54
Temperature: -35°C ~ +85°C
Certifications: ATEX, IECEx, CSA, CE, RoHS, SIL2/3
IV. Accessories (5m system)
Probe: 330191-00-26-05-00 (8mm, 5m integrated cable, explosion-proof)
Extension cable: not required (5m integrated)
Monitor: 3500/40 (vibration), 3500/42 (axial position)
V. Terminal blocks (panel type)
-24 VDC (power negative)
COM (common terminal)
OUT (signal output)
SHIELD (shielding layer)
VI. Installation points
Panel hole opening: 4 holes for fixed installation, compatible with the old model 3300
Gap setting: 1.27 mm (-9 VDC), adjust by measuring the voltage between COM and OUT with a multimeter
Cable: bending radius ≥ 25mm,严禁 cutting; single end grounding of the shielding layer at the cabinet end