330180-90-00
Description
I. Model Interpretation
330180: 3300 XL 8mm Eddy Current Preprocessor (50Ω System) 90
9: Total system length 9m (probe + extension cable)
0: Panel mounting
00: Standard configuration, without explosion-proof / safety certification
II. Technical Specifications (Electrical)
System impedance: 50 Ω (must match 50Ω probe / cable)
Power supply voltage: -17.5 ~ -26 VDC (typical -24 VDC)
Working current: ≤ 12 mA
Sensitivity: 7.87 mV/μm (200 mV/mil)
Linear range: 0.25 ~ 2.3 mm (10 ~ 90 mils)
Frequency response: 0 ~ 10 kHz (+0/-3dB)
Output signal: Negative DC voltage, proportional to the gap (static displacement + dynamic vibration)
Signal transmission distance: Up to 305m from preamplifier to monitor (three-core shielded wire)
Environmental and mechanical
Operating temperature: -35°C ~ +85°C
Storage temperature: -35°C ~ +100°C
Installation method: Panel mounting (4-hole fixed), with built-in electrical isolation for base
Dimensions: 81.3 × 35.1 × 63.5 mm
Weight: Approximately 0.25 kg
Shell material: A308 aluminum alloy
Protection level: IP54 (correct installation)
Certifications: CE, RoHS (no explosion-proof / SIL)
III. Supporting Components (9m System)
Probe: 330191-00-26-10-00 (8mm, 4m integrated cable, standard temperature)
Extension cable: 330130-08-05-02 (5m, 50Ω)
Monitor: 3500/40 (vibration), 3500/42 (axial position)
IV. Installation Tips
Impedance matching: Full length 50Ω, cannot be mixed with 75Ω system
Recommended gap: 1.27 mm (50 mils, approximately -9 VDC)
Cable handling: Do not cut; bending radius ≥ 25mm, avoid sharp bends
Shield grounding: Single-ended grounding at cabinet end, floating at probe end
Installation insulation: Base comes with insulation, no additional insulation board required
V. Differences from 330180-90-05
330180-90-00: Standard type, no explosion-proof certification, for ordinary industrial environments
330180-90-05: With CSA/ATEX/IECEx explosion-proof certification, for hazardous areas