330180-91-00
Description
I. Model Interpretation
330180: 3300 XL 8mm Eddy Current Preprocessor (50Ω System) 91
9: Total system length 9m (probe + extension cable)
1: DIN rail installation
00: Standard configuration (no special certification / no armor / no special cable length)
II. Technical Specifications (Electrical)
System impedance: 50 Ω (must match 50Ω probe / cable)
Power supply voltage: -17.5 ~ -26 VDC (typical -24 VDC)
Working current: ≤ 12 mA
Sensitivity: 7.87 mV/μm (200 mV/mil)
Linear range: 0.25 ~ 2.3 mm (10 ~ 90 mils)
Frequency response: 0 ~ 10 kHz (+0/-3dB)
Output signal: Negative DC voltage, proportional to the gap (static displacement + dynamic vibration)
Environmental and mechanical
Operating temperature: -35°C ~ +85°C
Storage temperature: -35°C ~ +100°C
Installation method: DIN rail (35mm), with built-in insulating base
Size: 81.3 × 35.1 × 63.5 mm
Weight: Approximately 0.25 kg
Shell material: A308 aluminum alloy
Protection level: IP54 (correct installation)
Certifications: SIL 2/3, ATEX, CSA, CE, RoHS
III. Supporting Components (9m System)
Probe: 330191-00-26-10-00 (8mm, 4m integrated cable, standard temperature)
Extension cable: 330130-08-05-02 (5m, 50Ω)
Monitor: 3500/40 (vibration), 3500/42 (axial position)
IV. Installation Tips
Impedance matching: Full length 50Ω, cannot be mixed with 75Ω system
Recommended gap: 1.27 mm (50 mils, approximately -9 VDC)
Cable handling: Do not cut; bending radius ≥ 25mm, avoid sharp bends
Shielding grounding: Single-ended grounding at the cabinet end, floating at the probe end
Installation insulation: Preamplifier base comes with insulation, no additional insulating board required
V. Typical Applications
Large steam turbines, compressors, fans, motors, pumps for shaft vibration / shaft displacement monitoring
Suitable for long distances (9m) + high-density DIN cabinet installation scenarios