330780-90-00
Description
Model Explanation
330780: 11mm XL Series Preamplifier
90: System total length 9.0m, panel installation (Panel Mount)
00: No explosion-proof certification, ordinary industrial grade
Core Parameters (Electrical)
Adapter probe: 3300 XL 11mm (as 330781)
Sensitivity: 3.94 V/mm (100 mV/mil) ±10%
Linear range: 0.5~4.5 mm (4mm effective linear)
Frequency response: 0~8 kHz
Power supply: -17.5~-26 VDC (without safety barrier); -23~-26 VDC (with safety barrier)
Output: Gap voltage (proportional to gap)
Mechanical and Environmental
Installation: Panel installation (Panel Mount)
Shell: Cast aluminum, blue
Protection: IP65
Operating temperature: -40℃~+85℃
Explosion-proof: None (00)
System Adaptation (9m Complete Set)
Probe: 330781-90-00 (11mm, 9m, panel installation)
Extension Cable: 330784-090-11-00
Monitoring Module: 3500/42 (shaft vibration), 3500/45 (displacement), etc.
Difference from 330780-91-00
330780-90-00: Panel installation (Panel Mount)
330780-91-00: DIN rail installation
The electrical parameters are the same, only the installation method is different.
Installation Points
The total length of the entire system must be strictly 9.0m (probe + cable + preamplifier internal)
Shielded wire single-ended grounding (on the preamplifier side)
For non-explosion-proof steam turbines, fans, compressors, etc. shaft vibration/positioning monitoring.