330850-90-05
Description
Model Explanation
330850: 25mm differential expansion dedicated preamplifier
90: Total system length 9.0 meters
05: Multiple explosion-proof safety certifications
Core Parameters
Electrical Parameters
Matching sensitivity: 0.787V/mm
Linear range: 0 - 12.7mm
Frequency response range: 0 - 5kHz
Power supply voltage: 18 - 30VDC
Output gap voltage analog signal
Mechanical Specifications
Installation method: Panel-mounted installation
Shell material: Cast aluminum
Protection level: IP65
Environmental Parameters
Operating temperature: -40℃ - 85℃
Storage temperature: -51℃ - 105℃
Explosion-proof grade: Ex ia IIC T4
System Compatibility
Matching probe: 330851 series 9.0m specification probe
Matching cable: 330854 series 9.0m specification cable
Compatible rack: 3300 TSI, 3500 TSI
Compatible module: 3500/45M differential expansion displacement module
Installation Specifications
The entire system length is uniformly 9 meters
Insulation installation of the base, reducing signal interference
Shielded wire is only single-ended grounded on the preamplifier side
Explosion-proof site construction in accordance with standards Applicable scenarios
Detection of shaft misalignment and shaft displacement for large steam turbine generators
Long-distance wiring, high-temperature environments, and explosion-proof areas in chemical plants
Get a Quote