330851-02-000-070-50-00-05
Description
Model Explanation
330851: Special probe for 25mm differential expansion
02: Conventional M30×2 threaded housing
000: Standard size without threaded section
070: Total system length 7.0 meters
50: High-temperature armored protective cable
00: Tail-out structure
05: Multi-certification for explosion-proof
Core Parameters
Electrical Parameters
Sensitivity: 0.787V/mm
Linear range: 0 - 12.7mm
Frequency response: 0 - 5kHz
Output negative pressure gap voltage signal
Mechanical Specifications
Installation thread: M30×2
Outlet method: Tail-out
Total cable length: 7m
Minimum bending radius: ≥60mm
Protection level: IP67
Environmental Parameters
Probe short-term temperature resistance: 150℃
Cable temperature resistance range: -40℃ - 120℃
Anti-vibration grade: 10g
Explosion-proof grade: Ex ia IIC T4
System Compatibility
Matched preamplifier: 330850-070-05
Matched extension cable: 330854-070-25-05
Compatible rack: 3300 TSI, 3500 TSI
Compatible module: 3500/45M differential expansion displacement module
Installation Points
The overall length specification of the system remains consistent
Armored cable should avoid severe bending and crushing
Shielded wire is only grounded on one side of the preamplifier
Explosion-proof site should be constructed in accordance with standard specifications Applicable scenarios
Steam turbine, generator differential expansion and shaft displacement detection
Severe mechanical wear, long-distance wiring conditions
High-temperature plant, hydrogen generator, chemical explosion-proof area