330876-02-10-00-00
Description
I. Model Interpretation
330876: Special probe for 50mm range
02: M14×1.5 metric thread, lateral outlet structure
10: Total system length 1.0 meter
00: Non-armored high-temperature insulated cable
00: Without explosion-proof certification, suitable for ordinary industrial areas
II. Core Parameters
Mechanical Specifications
Thread Specification: M14×1.5
Shell Material: 316 stainless steel
Inductive End: Ceramic material, resistant to hydrogen corrosion and aging
Cable Type: FluidLoc high-temperature insulated sheathed cable
Overall Length: Built-in cable 1.0m
Minimum Curvature Radius: ≥50mm
Protection Grade: IP67
Electrical Performance
Measurement Range: 0~50mm
Effective Linear Range: 2~45mm
Standard Sensitivity: 40mV/mm
Frequency Response: 0~5kHz
Output Signal: -24V~0VDC Gap Voltage
Environmental Parameters
Probe Working Temperature: -40℃~+85℃
Cable Tolerance Temperature: -40℃~+120℃
Anti-Vibration Grade: 10g
Applicable Medium: Conventional oil and gas, hydrogen cooling unit environment
III. System Compatibility
Matching Preamplifier: 330878-10-00
Compatible Monitoring Rack: 3300 TSI, 3500 TSI
Compatible Function Modules: 3500/40M Vibration Module, 3500/45M Displacement Module, 3500/50M Speed Phase Module
Compatible Measured Material: 4140 steel
IV. Installation and Commissioning
Standard Installation Gap Recommendation: 10~40mm
Typical Working Gap: 20mm, Corresponding Output Voltage ≈ -16V
Installation Tightening Torque Control: 25Nm
Probe Shell and Equipment Remain Insulated, Shielding Wire Single-ended Grounding
Cable Prohibition of Cutting and Splicing, Avoid Hard Objects Compression and Bending
V. Comparison of the Same Model
330876-02-10-00-00: 1-meter short cable, non-armored without explosion-proof, close-range conventional conditions
330876-02-50-00-00: 5-meter cable, compatible with medium-distance wiring
330876-02-90-00-00: 9-meter long cable, long-distance on-site wiring
VI. Application Scenarios
Short-distance point monitoring of steam turbines, water turbines, large compressors
Displacement and vibration detection of hydrogen cooling power generation units
High-temperature conditions in ordinary factories, not suitable for flammable and explosive hazardous areas
Get a Quote