330900-50-00
Description
I. Model Analysis (330900-A-B)
330900: Special installation housing for 3300 XL NSv probe
50: Shell length 5.0 in (127mm)
00: Standard configuration (no special options)
II. Core Parameters
1. Mechanical Specifications
Material: Stainless steel (316SS), corrosion-resistant and durable
Length: 127mm (5.0in)
Compatible probes: 330901 (1/4-28), 330908 (3/8-24) etc. NSv series
Installation method: Threaded fixation (matching probe outer diameter)
Sealing: Viton® O-ring, withstands -40°C to +120°C
Protection level: IP67 (dust and water protection)
Weight: Approximately 0.15kg
2. Application Scenarios
Narrow spaces: Through holes, limited side view, insufficient depth installation positions
Small shaft diameters: Radial vibration/ displacement measurement for shafts with a diameter of < 51mm
Harsh environments: Oil and gas, chemical, power generation, etc. high-temperature / humid / vibration conditions
III. System Compatibility (must be a complete set)
1. Compatible with probes (example)
330901-00-13-05-02-00 (1/4-28 thread, ultra-short housing)
330908-09-51-05-02-05 (3/8-24 thread, short housing explosion-proof)
2. Complete system composition
Probe: 3309XX (NSv series)
Housing: 330900-50-00 (installation fixation)
Extension cable: 330930-XXXX (matching length)
Preamplifier: 330980-50-00 (5m system)
Monitoring module: 3500/40M (vibration), 3500/50M (phase)
IV. Comparison with similar models Table
Model Length Material Compatible Probe Scene
330900-50-00 127mm 316SS 330901/330908 Standard length, universal
330900-70-00 177.8mm 316SS 330901/330908 Long body, deep hole installation
V. Installation Tips
Thread Matching: Ensure that the shell thread is completely consistent with the probe thread (1/4-28 or 3/8-24).
Sealing Installation: The O-ring must be in place to prevent oil or water vapor from entering and affecting measurement accuracy.
Insulation Floating: The shell is insulated from the equipment to prevent ground current interference with the signal.
Length Matching: Probe cable + extension cable = nominal length of the preamplifier (e.g., 0.5 + 4.5 = 5.0m).
VI. Common Confusion Clarification
❌ Not a probe: Probe model is 330901/330908 (with 6-digit code).
❌ Not a preamplifier: Preamplifier model is 330980 series (blue shell).
✅ Shell: Only for mechanical installation, without electronic components.
Get a Quote