PCI-6519
Description
Model: PCI‑6519
Part Number: 779085‑01
Brand: National Instruments (NI)
Series: 651x Industrial Isolated DIO
Bus: PCI (5 V, half‑length)
Connector: 1 × 37‑pin D‑Sub
Isolation: 2 optically isolated banks (Bank 0: 16 DI; Bank 1: 16 DO)
Driver: NI‑DAQmx
Operating Temp: 0 ~ 55 °C
Features: ±30 V, 16 sink/source inputs + 16 sink outputs, bank isolation, watchdog, programmable power‑on, low cost
I. Digital Inputs (DI) – 16 ch, isolated, sink/source
Channels: 16 isolated digital inputs (Bank 0)
Voltage Range: ±30 VDC
Logic Thresholds: Low ≤ +4 V, High ≥ +11 V
Input Type: sink or source configurable
Filtering: programmable debounce filters per channel
Max Rate: ~100 kHz (software dependent)
Functions: change detection, event counting, status monitoring
II. Digital Outputs (DO) – 16 ch, isolated, sink
Channels: 16 isolated digital outputs (Bank 1, sink)
Voltage Range: 0 ~ +30 VDC (sink, low active)
Load Current:
Continuous: 120 mA/channel
Peak: 500 mA/channel
Output Type: sink (pulls load to ground)
On‑Resistance: < 1 Ω (typical)
Power‑On State: programmable (high/low/hold)
Max Switching Rate: ~100 kHz
Functions: single/group control, pulse, software PWM, watchdog safety
III. Industrial Features
Watchdog Timer: 1–65535 ms; fault → safe state (high/low)
Programmable Power‑On: prevents unexpected actuation
Dual‑Bank Isolation: DI bank / DO bank isolated from each other & system ground
Overcurrent Protection: per‑channel current limiting
High CMR: robust for motors, inverters, relays
IV. Physical & Environmental
Size: half‑length PCI, ~12.4 × 12.6 × 2.2 cm
Weight: ~0.15 kg
Temperature: 0 ~ 55 °C (oper), −20 ~ 70 °C (storage)
Humidity: 10%–90%, non‑condensing
Isolation Voltage: ≥ 500 Vrms (banks to system ground)
Power: +5 V @ ~150 mA; +3.3 V @ ~300 mA
V. Wiring Highlights
DI (sink/source): sensor to +24 V or GND; threshold +4 V low / +11 V high
DO (sink): load between +24 V and DO; DO low = ON
Inductive loads: add 1N4007 freewheeling diode across coil
Shielding: shield to isolated field ground, not system ground
VI. Core Advantages & Applications
16 isolated DI (sink/source) + 16 isolated sink DO, ±30 V, 120 mA continuous sink outputs
Dual‑bank optical isolation, watchdog, programmable power‑on, NI‑DAQmx, half‑length PCI
Ideal for 24 V industrial sensors + sink‑type relay/valve control, mixed I/O, manufacturing test, industrial automation










Get a Quote