MVME162-200
Description
MVME162-200 (Motorola/Emerson, 68LC040 base model)
Position: The simplest configuration of the MVME162 series - 25 MHz, no FPU, 1MB, no network, no SCSI, 2×IP, 4×serial ports; the least memory and the fewest interfaces.
I. Basic Information
Model: MVME162-200
Brand: Motorola / Emerson
Form: 6U VME64 single-board computer (SBC)
CPU: MC68LC040 @ 25 MHz (❌ no FPU, ✅ MMU, 8KB Cache)
Key features: 1MB memory, no network, no SCSI, 2×IP, 4×serial ports
II. Core Hardware Specifications
1) Processor
MC68LC040, 25 MHz
❌ No FPU (no floating point); ✅ MMU + 8KB unified cache
Performance: Approximately 15 MIPS, only integer operations
2) Memory (Key point: 1MB, minimum)
DRAM: 1 MB (parity check)
SRAM: 128 KB, battery backup
Flash: 1 MB
NVRAM/RTC: 8 KB + real-time clock, battery backup
3) I/O Interfaces (Minimal: No network, no SCSI, 2 IP, 4 serial ports)
VMEbus: VME64 A32/D32, master/slave, DMA, system controller
Ethernet: ❌ No onboard network interface
Serial ports: 4×RS-232 (Console + 3 configurable)
SCSI: ❌ No SCSI
IP slots: **2×IndustryPack (IP) ** expansion slots (2 less than 10/12/13)
Parallel ports: None
4) Electrical / Environmental
Power supply: +5 V @ 3.5 A
Operating temperature: 0 ℃ ~ +70 ℃
Size: 6U VME (233 × 160 mm)
III. MVME162-10 / 200 Minimal Comparison (Plain Text)
10: LC040/25/❌ FPU/4MB/❌ Network /❌ SCSI/4IP/2 Serial Ports → Basic Model
200: LC040/25/❌ FPU/1MB/❌ Network /❌ SCSI/2IP/4 Serial Ports → Ultra-Simplified Model
IV. Functional Features
Minimum configuration of the series: 1MB memory, 2 IP slots, no network, no SCSI, lowest cost
Multiple serial ports: 4 RS-232, suitable for multi-serial port device control (such as multiple instruments / sensors)
No floating point, no extended storage: only suitable for simple integer control, no local storage scenarios
Basic power-off protection version: SRAM/NVRAM/RTC battery backup
V. Typical Applications
Ultra-low-cost VME control: simple logic, no network, no storage, multiple serial ports
MVME162-10 downgrade replacement: budget limited, no need for 4MB/4IP, use 200 to reduce cost
Industrial equipment multi-serial port acquisition: 4 serial ports for multiple sensors / instruments, no complex operations

Get a Quote