HONEYWELL PW6K1R2 C031006: PW-Series Dual Reader Access Control Module Product Description
Description
HONEYWELL PW6K1R2 C031006: PW-Series Dual Reader Access Control Module Product Description
Brand and Product Identification
The HONEYWELL PW6K1R2, with identification reference C031006, is a PW-Series dual reader access control module for the Honeywell PW-6000 modular access control system. The PW6K prefix identifies the PW6000 access module family, R2 identifies the two-reader module variant, and C031006 is the unit or internal manufacturing reference associated with this board. The PW6K1R2 provides connections for two card access readers, supervised alarm inputs and relay door or facility outputs, and communicates with the PW6K1IC or PW3K1IC intelligent control module over a supervised RS485 bus.
Product Function and System Role
The PW6K1R2 supports up to two access control doors by providing reader connections, supervised inputs and relay outputs for door and access control functions. The module receives card or keypad data from connected readers, monitors door position, request to exit, tamper and alarm inputs, and operates relay outputs for door strikes, maglocks, status annunciation or general facility control. It is an access control reader and I/O module, not the intelligent controller, card reader, electric lock, power supply, panel enclosure or server software by itself.
Reader Port Specifications
The PW6K1R2 has two reader ports. Each reader port supplies 12 V DC at 50 mA and supports clock/data or data0/data1 reader interface signals. Keypad data is multiplexed with card data. The module supports two-wire or one-wire bi-color LED control, and buzzer support is available only with one-wire LED control. Reader wiring uses six-conductor 18 AWG cable according to the Honeywell wire requirements. The module supports Wiegand, magnetic stripe, proximity and keypad reader technologies through the compatible reader interface formats.
Alarm Inputs and Relays
The PW6K1R2 has eight supervised general purpose alarm inputs with programmable circuit type. Only six general purpose inputs are available when the module is installed in a PW5K2ENC1 or PW5K2ENC2 enclosure. Two dedicated alarm inputs monitor tamper detection and power loss. The module has two general purpose form-C output relays rated 5 A at 28 V DC, and four general purpose form-C output relays rated 2 A at 28 V DC; only two of the 2 A relays are available in the PW5K2ENC1 or PW5K2ENC2 enclosure configuration. Input circuits support normally open, normally closed, non-supervised and supervised wiring with correct end-of-line resistance.
Communication Specifications
The PW6K1R2 connects to the intelligent control module through an RS485 supervised bus. Standard communication speed is 38,400 bps. Total RS485 bus length is 4000 feet, or 1250 meters. RS485 wiring uses 24 AWG, two twisted pairs with shield, such as Belden 9842 or equivalent, with 120 ohm characteristic impedance and 23 pF per foot capacitance. The PW6K1R2 also has an RS485 serial port to facilitate communications to third-party reader and field device controllers. Up to 32 I/O or reader modules may connect to the PW6K1IC RS485 ports.
Physical and Environmental Ratings
The access module board dimensions are 9.0 inches high, 5.5 inches wide and 1.0 inch deep, equivalent to 228.6 mm high, 139.7 mm wide and 25.4 mm deep. Operating temperature range is 0 to 70 degrees Celsius, and storage temperature range is minus 55 to plus 85 degrees Celsius. Operating humidity is 0 to 95 percent relative humidity non-condensing. The module can be rack mounted, wall mounted or flat mounted according to the PW-Series enclosure configuration.
System Features and Modes
The PW-Series modules are controlled by the PW6K1IC or PW3K1IC intelligent control module, and hardware interface configuration options are stored in the intelligent controller. In the event communication to the intelligent control module is lost, each reader can be individually configured for off-line operation, including facility code access, locked with no access, or unlocked with full access. Reader operating modes include locked, unlocked, facility code, card only, card and PIN, card or PIN and PIN only. The module supports anti-passback features including free pass and exempt flags, last area accessed, last reader accessed and time or date of last access.
Typical Application Scenarios
Typical applications include two-door access control in office buildings, production facilities, laboratories, server rooms, warehouses, pharmaceutical or clean areas, parking control, elevator access and secured perimeter doors. The dual reader module suits two readers on one door for entry and exit supervision, or two separate doors on one PW6K1R2 board. Supervised inputs monitor door contacts, request-to-exit devices, glass break or motion inputs where configured, while relays control electric strikes, magnetic locks, door accessories or alarm signaling.
Installation and Configuration Notes
Installation should follow the Honeywell PW-6000 installation manual, enclosure wiring diagrams, access control system design and local security or electrical codes. Mount the board in the selected PW5K2ENC1, PW5K2ENC2 or PW5K1ENC3 enclosure, connect the RS485 bus to the intelligent controller, wire the two reader ports, supervised alarm inputs and relay outputs, and configure reader format, input circuit type, relay logic, off-line mode and door timing in the PW-Series controller or Pro-Watch system. Verify reader operation, door monitoring, relay control, tamper and power loss supervision, and offline behavior after commissioning.
Advantages and Selection Notes
The PW6K1R2 provides two reader ports, eight general purpose supervised inputs, two dedicated tamper and power inputs, six form-C relay outputs in the full enclosure configuration, RS485 module and third-party device communication, programmable NO or NC and supervised or non-supervised circuits, and flexible offline door states for security continuity. When selecting a replacement, confirm PW6K1R2 versus PW5K1R1 single reader or PW6K1IN and PW6K1OUT dedicated input or output modules, enclosure configuration, available inputs and relays, reader interface, RS485 wiring and controller compatibility. The PW6K1R2 is a reader and I/O access module, not the controller, reader, lock, power supply, enclosure or access control software; its role is to interface doors, readers, inputs and relays to the PW-6000 intelligent controller.
Get a Quote