Description

TELEMECANIQUE LP2K0601FD Product Description

Overview

TELEMECANIQUE LP2K0601FD is a Schneider Electric TeSys K pre-assembled reversing magnetic contactor for three-phase motor forward and reverse control. Public Schneider and distributor records identify the unit as a two-three-pole reversing contactor with mechanical interlock, screw connections, 6 A rated operational current at 440 V AC under AC-3, and 110 V DC control coil. It is a direct motor-control replacement spare for existing Telemecanique or Schneider TeSys K starter installations.

Features

The LP2K0601FD reversing contactor assembly contains two contactors, each 3P with 3 NO power poles, and 1 NC auxiliary contact per contactor, giving 0 NO and 2 NC auxiliary contacts overall in the public record. The mechanical interlock prevents the two reversing contactors from closing at the same time. Screw-clamp terminals support panel or starter wiring in conventional industrial control assemblies.

Public distributor data lists control voltage as nominal 110 V DC, with DC control range 88 to 126.5 V DC. Rated operational voltage Ue reaches up to 690 V. Protection degree is IP20. Rated active power is listed as 1.5 kW at 220 to 230 V AC up to 3 kW at 660 to 690 V AC, under AC-3 utilization category.

A public used-unit record lists conventional contactor insulation reference values Ith 20 A, Ui 690 V, Uimp 8 kV, and standards IEC/EN 60947-4-1, IEC/EN 60947-5-1 and JIS C 8201-4-1. AiEMA datasheet summary lists contact current rating 6 A, power rating 3 kW, coil voltage 110 V DC, mounting style screw, and operating temperature range -25 to +50 degrees Celsius. Mechanical durability is listed by distributor data as 5,000,000 no-load operations.

Specs

Brand: TELEMECANIQUE / Schneider Electric Series: TeSys KModel: LP2K0601FDProduct type: Pre-assembled reversing magnetic contactor Poles: 2 × 3P; 2 × 3 NO power poles Auxiliary contacts: 0 NO, 2 NC; 1 NC on contactor A and 1 NC on contactor B Rated operational current: 6 A at 440 V AC, AC-3Rated operational voltage Ue: Up to 690 VCoil voltage: 110 V DC nominal Control voltage range: 88 to 126.5 V DCAC-3 rated active power: 1.5 kW at 220 to 230 V AC; 3 kW at 660 to 690 V ACInsulation voltage reference Ui: 690 V per used-unit record Impulse withstand Uimp: 8 kV per used-unit record Thermal current Ith: 20 A per used-unit record Protection degree: IP20Connection: Screw terminals or screw clamp Interlock: Mechanical interlock between reversing contactors Mounting: Screw mounting per datasheet summary Mechanical durability: 5,000,000 no-load operations per distributor record Operating temperature: -25 to +50 degrees Celsius per summary Standards: IEC/EN 60947-4-1, IEC/EN 60947-5-1, JIS C 8201-4-1 per public record Product status: Existing-installation reversing motor starter spare

Principle

A reversing contactor switches the phase sequence supplied to a three-phase motor so that one contactor energizes for forward direction and the other for reverse direction. The two power contactors are mechanically interlocked so that both cannot pull in together, which reduces the risk of phase-to-phase short circuit. Auxiliary NC contacts are commonly used for control-circuit interlocking, status signaling or safety-related prevention of simultaneous coil energization.

The DC coil is energized through a forward or reverse pushbutton, PLC output, relay output or motor protection circuit. When the forward contactor closes, its three power contacts connect the supply phases to the motor in one phase sequence; when the reverse contactor closes, two phases are exchanged to rotate the motor in the opposite direction. Replacement should verify coil voltage and type, contact configuration, power pole count, auxiliary contact arrangement, terminal layout, interlock condition, motor protection rating, wiring diagram, coil suppressor or surge suppressor fitting, and mounting footprint.

Applications

TELEMECANIQUE LP2K0601FD is used for forward and reverse control of small three-phase motors on hoists, winches, cranes, elevators, conveyor belts, gate or valve drives, pumps, compressors, machine tools, packaging machines, textile machinery, material handling, production lines and small motor starters. In legacy Telemecanique or Schneider TeSys K panels, it serves as a direct replacement reversing contactor spare when the coil voltage, contact arrangement, motor power, utilization category, terminal wiring and mounting match the original unit.