SIEMENS 6SL3210-5BB13-7UV0 Product Description
November 14, 2026

SIEMENS 6SL3210-5BB13-7UV0 Product Description

SIEMENS 6SL3210-5BB13-7UV0 Siemens SINAMICS V20 0.37 kW 230V inverter drive spare V20 FSA Modbus RTU USS motor speed controller replacement

Description

SIEMENS 6SL3210-5BB13-7UV0 Product Description

Overview

SIEMENS 6SL3210-5BB13-7UV0 is a SINAMICS V20 basic inverter for speed control of a three-phase asynchronous motor. The Siemens datasheet identifies the drive as size FSA, single-phase 200 to 240 V AC input, with three-phase 230 V motor output, rated power 0.37 kW / 0.50 hp and rated current 2.30 A. It is a compact V20 drive spare for existing fan, pump, conveyor, machine or general industrial variable-speed applications.

Features

The drive accepts one-phase line voltage 200 to 240 V AC, tolerance +10 percent / -10 percent, at line frequency 47 to 63 Hz. Output supplies a three-phase 230 V motor with rated power 0.37 kW and rated current 2.30 A. Output frequency is 0 to 550 Hz with pulse frequency 2 kHz.

The V20 unit provides four standard digital inputs, one relay changeover contact digital output, one transistor digital output and two analog inputs that can also be used as additional digital inputs. Communication supports USS and Modbus RTU. Cooling is convection with a 1000 m reference condition listed in the datasheet record.

Overload capability is listed as Low Overload 110 percent rated output current for 60 s, cycle time 300 s, and High Overload 150 percent rated output current for 60 s, cycle time 300 s. The drive degree of protection is IP20, size FSA, net weight 1.00 kg. Dimensions listed are width 90.0 mm, height 150.0 mm and depth 145.5 mm.

Maximum motor cable length is 25 m shielded and 50 m unshielded. Standards listed include CE, cULus, C-tick, KC, EN 61800-5-1, EN 60204-1 and EN 61800-3. Efficiency is listed at 0.98, power factor λ 0.72 and offset factor cos φ 0.95.

Specs

Brand: SIEMENSProduct series: SINAMICS V20Order number: 6SL3210-5BB13-7UV0Product type: Basic inverter or variable-frequency AC drive Frame size: FSAInput phases: 1 ACInput line voltage: 200 to 240 V AC, +10 percent / -10 percentLine frequency: 47 to 63 HzOutput phases: 3 ACOutput rated voltage: 230 VRated power: 0.37 kW / 0.50 hpRated output current: 2.30 AOutput frequency: 0 to 550 HzPulse frequency: 2 kHzDigital inputs: 4 standard Digital relay outputs: 1 changeover contact Digital transistor outputs: 1Analog inputs: 2, usable as additional digital inputs Analog outputs: Not listed in datasheet record Communication: USS, Modbus RTUCooling: Convection Protection degree: IP20Mounting: Wall mounting or side-by-side design Overload LO: 110 percent rated current for 60 s, cycle 300 sOverload HO: 150 percent rated current for 60 s, cycle 300 sMaximum motor cable: 25 m shielded; 50 m unshielded Net weight: 1.00 kgWidth: 90.0 mmHeight: 150.0 mmDepth: 145.5 mmEfficiency: 0.98Power factor λ: 0.72Offset factor cos φ: 0.95Conformity: CE, cULus, C-tick, KCStandards: EN 61800-5-1, EN 60204-1, EN 61800-3Product status: Legacy V20 inverter spare for existing motor-control installations

Principle

The V20 inverter converts single-phase AC supply into a variable-voltage, variable-frequency three-phase output for an asynchronous motor. The drive rectifies the incoming supply, supplies the DC bus, and modulates the output through pulse-width modulation to control motor speed and torque according to the commanded frequency or speed reference.

Digital inputs can receive start, stop, direction, reset or speed-selection signals from a PLC, pushbuttons or machine controls. Relay or transistor outputs provide run, fault or warning status to external circuits. Analog inputs can receive speed reference signals such as 0 to 10 V or potentiometer references, while Modbus RTU or USS allows serial communication with a PLC or HMI.

Replacement should verify the original drive order number, input voltage, motor voltage, motor power, motor current, control wiring, communication protocol and address, speed reference, I/O configuration, brake or stop requirement, cable shielding, mounting space and drive parameter backup. V20 inverters contain hazardous DC bus voltage after power-off; installation and servicing should be performed by qualified personnel following Siemens manuals, lockout, tagout and discharge procedures.

Applications

SIEMENS 6SL3210-5BB13-7UV0 is used for speed control of small three-phase motors on fans, pumps, compressors, conveyors, packaging machines, material handling, machine tools, textile or printing equipment, feeders, mixers, HVAC, small production machinery and general industrial drives. In existing V20 installations, the inverter serves as a direct replacement drive spare when the motor rating, supply voltage, I/O, communication, mounting and parameter configuration match the original unit.


Get a Quote