Description
MANTRACOURT ADP15 ADP15-TLQ-V2-0-R3-12/24-P/G Product Description
Overview
MANTRACOURT ADP15 ADP15-TLQ-V2-0-R3-12/24-P/G is a Mantracourt ADP15 digital panel indicator or controller for load cell, strain, pressure, potentiometer or transducer-based measurement applications. The ADP15 series is a retired Mantracourt product used as a panel-mounted display, scaling and control unit for process and weighing signals. The supplied build code follows the ADP15 ordering pattern for supply, output module, software option, relay or control configuration, panel mounting and instrument version; public manual data confirms the ADP15 family and 12/24 V DC supply option, while exact suffix meanings for this unit should be verified against the ADP15 manual or instrument label.
Features
The ADP15 front panel provides a 4.5-digit red LED display with range -19999 to +19999, four flush-mounted membrane keys and three LED indicators. Two red LEDs indicate ON/OFF status of control set points, and the third red LED indicates program mode. The display can be scaled in real engineering units, with display freeze and peak hold features available from the keypad. User-entered parameters are stored in EEPROM and retained without backup power.
The ADP15 manual lists power supply options 220/230 V AC 50/60 Hz, 110 V AC 50/60 Hz, or 9 to 32 V DC, each with approximately 10 W power. The supplied suffix 12/24 corresponds to the DC supply option in the ADP15 build-code reference, with manual range 9 to 32 V DC and startup current about 3 A for 20 ms. The manual notes all supplies should be externally fused.
The ADP15 input can connect to DC, AC, pressure, strain gauge or potentiometer inputs according to the installed input configuration. For pressure or strain sensors, the ADP15 provides 10 V excitation with 150 mA supply current and sensitivity preset by DIP switch in mV/V ranges such as 0.5, 1.0, 2.5, 5, 10, 20, 50, 100 and 200 mV/V. Input excitation includes inductive and capacitive filtering for noise immunity.
Output modules are selected according to application. Analog output options include DC voltage ranges such as 0 to 1 V, 0 to 5 V, 1 to 5 V and 0 to 10 V, and DC current ranges such as 0 to 1 mA, 0 to 20 mA, 4 to 20 mA, 10 to 50 mA and 0 to 5 mA. Digital output options include relay driver or triac outputs with ON/OFF or PID control, latching output, set point and hysteresis settings, output inversion and adjustable ON or OFF time delays.
Specs
Brand: MANTRACOURTProduct family: ADP15 digital indicator or controller Build code: ADP15-TLQ-V2-0-R3-12/24-P/GProduct type: Panel-mounted digital measurement indicator and control unit Display: 4.5-digit red LED, range -19999 to +19999Keys: Four membrane keys Status LEDs: Two set-point status LEDs; one program-mode LED Power supply options: 220/230 V AC 50/60 Hz, 110 V AC 50/60 Hz, 9 to 32 V DCSupplied supply suffix: 12/24, corresponding to DC supply option Approximate power: 10 WDC startup current: About 3 A for 20 ms per ADP15 manual Sensor excitation: 10 V, 150 mA supply current for pressure or strain sensor input mV/V sensitivity ranges: DIP-selectable ranges including 0.5 to 200 mV/V per manual Analog output options: Voltage or current modules; exact module for supplied build code unconfirmed Digital output options: Relay or triac outputs; exact relay count and contact configuration unconfirmed Memory: Parameters stored in EEPROM Operating ambient temperature: -10 to 50 degrees Celsius per manual Humidity: 95 percent, non-condensing Mounting: Panel mounting per build-code suffix PExact suffix translation: Verify against ADP15 user manual and instrument label Product status: Retired Mantracourt ADP15 replacement panel indicator spare
Principle
The ADP15 receives a low-level or analog signal from a load cell, strain gauge, pressure transducer, potentiometer or other compatible transducer. The input signal is conditioned, scaled and digitized by the indicator controller, and the measured value is shown on the LED display in selected engineering units. Calibration, decimal point, range limits, set points, hysteresis, output scaling and control parameters are entered through the front keypad and stored in EEPROM.
When the measured value crosses a configured set point, the relay or triac output changes state for alarm, control, PID or interlock action according to the configured output module. An analog output module converts the displayed input value or PID power level into a voltage or current signal for a recorder, PLC, drive, valve controller or other receiving device. The ADP15 operates as a panel-mounted measurement and control unit within a compatible process, weighing or monitoring system.
Replacement should verify the supply voltage, input signal type and transducer excitation, output module type and range, relay contact configuration, set-point or PID configuration, panel cutout, wiring, scaling and calibration data. Because the ADP15 is retired, the replacement should match the original build code, input configuration, output module, supply option and calibration settings before commissioning.
Applications
MANTRACOURT ADP15 ADP15-TLQ-V2-0-R3-12/24-P/G is used in legacy Mantracourt-based weighing, load measurement, pressure monitoring, strain measurement, force measurement, process indication and alarm control applications. Typical installations include hopper or tank weighing, platform scales, load cell indicators, material handling force monitoring, presses, packaging machinery, process monitoring, pump or compressor control, test benches, material handling and general industrial measurement panels. In existing ADP15 installations, the unit serves as a direct replacement panel indicator spare when the supply, input, output, scaling, calibration and panel mounting match the original instrument.