F3430
May 14, 2026

F3430

HIMA F3430 (4-channel safety relay output module) I. Product Overview Model: F3430 Brand: HIMA Black Horse (Germany) Series: HIMatrix F3 / H41q / H51q Safety System Type: 4-channel fail-safe relay output module (4-Fold Relay Module) Safety Level: SIL3 (IEC 61508), PL e, AK6, Cat.4 (TÜV Certified) Application: SIS/ESD/BMS/F&G; drives solenoid valves, contactors, alarm lights, small actuators Installation: Standard 4TE rack, supports hot swapping

Description

HIMA F3430 (4-channel safety relay output module)

I. Product Overview

Model: F3430

Brand: HIMA Black Horse (Germany)

Series: HIMatrix F3 / H41q / H51q Safety System

Type: 4-channel fail-safe relay output module (4-Fold Relay Module)

Safety Level: SIL3 (IEC 61508), PL e, AK6, Cat.4 (TÜV Certified)

Application: SIS/ESD/BMS/F&G; drives solenoid valves, contactors, alarm lights, small actuators

Installation: Standard 4TE rack, supports hot swapping

II. Electrical Parameters

Channels: 4 independent relays (SPDT single-pole double-throw)

Contact capacity: 250VAC / 30VDC, resistive 5A

Maximum switching voltage: 250VAC / 110VDC

Current per channel: Maximum 500mA (12W), short-circuit protection

Backplane power supply: 24VDC, power consumption ≤ 120mA

Insulation isolation: System side ↔ Field side 1500Vrms

Operating temperature: -20℃ ~ +60℃

Protection / Size: IP20; 4TE (≈ 20mm wide)

Weight: Approximately 0.15kg

III. Functions and Safety Features

Fault safety: Contacts safely open when power is lost / in case of failure to ensure safe shutdown.

Short-circuit protection: Each output can withstand short circuits without damaging the module.

Self-diagnosis: Full coverage diagnosis for coil / contact faults, short circuits, open circuits.

Status indication: LED per channel, power / fault LED, intuitive maintenance.

Redundancy compatibility: Supports QMR/TMR, meeting high safety redundancy architecture.

IV. Typical Applications

ESD emergency stop: Critical valves, actuator control

BMS boiler management: Fuel valve, igniter, purge valve

F&G fire protection system: Alarm horn, sprinkler valve, fire door interlock

Safety interlock: Third-party dry contact interface, low-power load drive

V. Comparison within the Series (Key Distinctions)

F3430: 4 channels, small size, low power consumption, 500mA, suitable for solenoid valves / coil-type loads

F3422: 8 channels, standard relay, 5A, universal type

F3423: 8 channels, relay amplification, stronger 24/48V drive, preferred for solenoid valves

VI. Wiring and Maintenance

Control input: 24VDC safety signal on system side

Output terminals: Each channel COM / NO / NC

Maintenance: Supports hot-swapping without downtime, online replacement

Software: SILworX / ELOP II configuration and fault diagnosis