HIMatrix F3417A (4-Relay Fail-Safe Amplifier) I. Basic Overview Model: F3417A Brand: HIMA (Black Horse) Series: HIMatrix F3 / H41q/H51q (HIQuad) Safety System Type: 4-Fold Fail-Safe Relay Amplifier Module Safety Level: SIL3 (IEC 61508), PL e (EN ISO 13849-1), AK6, Cat.4 (TÜV Certification) Applications: SIS/ESD/BMS/F&G, drives solenoid valves, small contactors, alarm lights and other field actuators Installation: Standard rack slots, supports hot swapping

Description

HIMatrix F3417A (4-Relay Fail-Safe Amplifier)

I. Basic Overview

Model: F3417A

Brand: HIMA (Black Horse)

Series: HIMatrix F3 / H41q/H51q (HIQuad) Safety System

Type: 4-Fold Fail-Safe Relay Amplifier Module

Safety Level: SIL3 (IEC 61508), PL e (EN ISO 13849-1), AK6, Cat.4 (TÜV Certification)

Applications: SIS/ESD/BMS/F&G, drives solenoid valves, small contactors, alarm lights and other field actuators

Installation: Standard rack slots, supports hot swapping

II. Core Electrical Parameters

Channel: 4 independent relay outputs

Input voltage: 24VDC or 48VDC

Output voltage: 24VDC or 48VDC, compatible with on-site actuators

Output current: 4A (per channel)

Backplane power supply: 24VDC, typical power consumption ≤ 130mA

Operating temperature: -20℃ to +60℃

Protection / Size: IP20; standard 4TE (approximately 20mm wide), size approximately 40×185×128mm

Weight: approximately 0.32kg to 1kg (slightly different for different batches)

III. Functions and Safety Mechanisms

Safety architecture: Quadruple redundancy (QMR), multiple fault safety implemented within a single module, contacts safely open in case of power loss or failure

Drive capability: Directly drives 24V/48V solenoid valves, small contactors, alarm horns, fire door interlocks, etc.

Self-diagnosis: Full-channel coverage self-diagnosis, detects coil / contact faults, short circuits, open circuits, power abnormalities

Operating mode: Each channel can be configured as fail-safe or non-fail-safe mode

Indicator lights: LED for each state, power/fault indicator lights, facilitating on-site maintenance

Isolation: Electrical isolation between channels, system side and field side, strong anti-interference capability

IV. Typical Application Scenarios

ESD emergency stop system: Key valves, actuator drives

BMS boiler management: Fuel valves, igniters, purge valves control

F&G fire protection system: Alarm horns, sprinkler valves, fire door interlocks

High-reliability interlock: Third-party system dry contact interface, safety barrier post-stage amplification

V. Comparison of Modules in the Same Series

F3417A: 4-redundant fault-safe relay amplifier, 24/48VDC, 4A / channel, SIL3

F3414: 4-channel standard safety relay output, 250VAC/5A, SIL3

F3405: 4-channel basic safety relay, 250VAC/5A, SIL3

F3430: 4-channel enhanced contact safety relay, ≤110VDC/250VAC, SIL3

VI. Wiring and Maintenance

Control input: System side 24VDC/48VDC safety control signal

Output wiring: Independent output for each channel, compatible with on-site loads (such as solenoid valve coils)

Maintenance: Supports hot swapping, can be replaced online without affecting system operation; diagnostic information can be read via SILworX/ELOP II software