Bosch Rexroth DKC01.3-016-7-FW Servo Drive
Description
Model Definition
DKC: ECODRIVE series drive controller
01.3: Hardware platform (Type 3, analog/parallel interface)
016: Rated continuous output current (16 A RMS)
7: High voltage class (700 V DC nominal bus, 400–480 V AC input)
FW: Firmware‑version unit (firmware ordered separately)
Technical Specifications
Electrical Parameters
Input voltage: 3‑phase 400–480 V AC, 50/60 Hz
Continuous output current: 16 A
Peak output current: 32 A (2× overload)
DC bus nominal voltage: 700 V DC
Control supply: 24 V DC ±20%
Compatible motors: MKD/MSK series synchronous servo motors (1.5–3 kW)
Max output frequency: 1000 Hz
Mechanical & Environmental Parameters
Dimensions (W×H×D): 100 mm × 350 mm × 250 mm
Weight: Approx. 5.2 kg
Operating temperature: 0 °C to +45 °C
Storage temperature: -25 °C to +85 °C
Protection class: IP20
Cooling: Internal forced‑air cooling (vertical mounting required)
Interface and Communication Configuration
Motor feedback: Incremental encoder (standard); absolute encoder (optional)
Digital I/O: 24 V DC inputs/outputs (enable, fault, limit, reference)
Control interfaces: Analog (±10 V) / pulse command (standard)
Communication: RS232/485 (standard); PROFIBUS DP, CANopen (optional cards)
Diagnostics: 7‑segment display + LED status indicators
Position blocks: 32 via I/O; 64 via serial communication
Core Functions
Torque, speed, and position control modes
2× overload capacity for dynamic acceleration/deceleration
FW firmware structure (order application firmware separately)
Built‑in homing, jog, and point‑to‑point positioning
Comprehensive protection: overvoltage, undervoltage, overcurrent, overtemperature, short circuit
Regenerative power capability
Application Scenarios
Medium‑power CNC machine tools (main/auxiliary axes)
Packaging, printing, and textile machinery
Automated assembly lines and material handling systems
400–480 V AC industrial automation environments
Retrofit of legacy Indramat DKC01.3 high‑voltage systems
Usage and Maintenance
Mount vertically with ≥80 mm bottom clearance and ≥150 mm top clearance for airflow
Verify input voltage matches 400–480 V AC rating before power‑on
Use shielded cables for motor/encoder wiring; separate from power cables
Clean cooling fans/filters every 3–6 months (dusty environments)
Check terminal connections quarterly for tightness
Commission via IndraWorks/DriveTop software with specified FW firmware