Bosch Rexroth DDS2.1-W150-D Digital Servo Drive
Description
Model Definition
DDS2.1: DDS02.1 series, compatible with DIAX02 system
W: Internal cabinet convection air cooling
150: 150 A continuous rated current, 300 A peak current
D: Digital servo feedback (DSF) interface (for digital encoders)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM units)
Control power: 24 V DC (20–28 V DC), 500 mA
Continuous output current: 150 A
Peak output current: 300 A (short‑term)
Current loop cycle: 125 μs
Speed loop cycle: 500 μs
Position loop cycle: 2 ms
Power dissipation: ~680 W
Compatible motors: MDD/MKD synchronous motors, LAR/LAF linear motors, 2AD series (with digital encoders)
Mechanical & Environmental
Cooling: Internal cabinet convection (W)
Protection class: IP20 (front), IP10 (unit)
Operating temperature: 0 °C to +45 °C; 20% derating at 55 °C
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m; 35% derating above
Dimensions (W×H×D): 150 mm × 408 mm × 180 mm
Weight: ~8.0 kg
Interface & Communication
Motor feedback: X4 interface for digital servo feedback (DSF) (encoder)
System bus: Shared 300 V DC bus (multi‑axis parallel)
Communication: Expansion slots for SERCOS, analog, or fieldbus modules
Digital I/O: 6 isolated inputs / 3 isolated outputs
Service port: RS232 (IndraWorks for setup/diagnostics)
Expansion slots: U1–U5 for I/O/functional modules
Core Functions
Three‑loop control (current/speed/position) for high precision
Dedicated digital encoder interface (D type) for DSF feedback
Internal convection cooling for standard cabinet installation
Comprehensive protection: overvoltage/undervoltage/overcurrent/short‑circuit/overtemperature/feedback loss
Control modes: torque/speed/position
Modular design for easy maintenance and expansion
Application Scenarios
Heavy‑load main axes of CNC machine tools (digital encoder motors)
Large textile, printing, packaging machinery
Heavy‑duty gantries, conveying lines, automated production lines
DIAX02 system retrofits requiring 150 A + digital feedback
Cabinet‑space‑limited equipment without external cooling
Usage & Maintenance
Ensure unobstructed cabinet airflow for cooling
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/control wiring before power‑on
Set parameters via IndraWorks (motor/load‑specific)
Clean heat sinks/air passages every 6 months; inspect terminals
Calibrate loops/encoder signals annually