Bosch Rexroth DDS2.1-W050-DA01-00 Digital Servo Drive
Description
Model Definition
DDS2.1: DDS02.1 series for DIAX02
W: Internal cabinet convection cooling
050: 50 A continuous / 100 A peak
D: Digital servo feedback (encoder)
A01: Analog interface module in U1
00: No firmware module included
Technical Specifications
Electrical
DC bus: 300 V DC ±15% (TVD/TVM supply)
Control power: 24 V DC (20–28 V DC)
Continuous current: 50 A
Peak current: 100 A (short‑term)
Control loops: Current 125 μs; Speed 500 μs; Position 2 ms
Power dissipation: ~220 W
Compatible motors: MDD/MKD synchronous servos, LAR/LAF linear motors (digital encoder)
Mechanical & Environmental
Cooling: Internal cabinet convection
Protection: IP20 (front), IP10 (unit)
Operating temp: 0 °C to +45 °C (20% derate at 55 °C)
Storage temp: -30 °C to +85 °C
Max altitude: 1000 m (35% derate above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 digital encoder interface (D‑type)
Command interface: Analog module A01 in U1 (±10 V speed/torque)
System bus: Shared 300 V DC bus (multi‑axis)
Digital I/O: 6 isolated inputs / 3 isolated outputs
Service port: RS232 (IndraWorks setup/diagnostics)
Expansion slots: U1–U5 (U1=A01; U5 for firmware, ordered separately)
Core Functions
Three‑loop control (current/speed/position) for high precision
Digital feedback for high resolution and noise immunity
Analog command for traditional ±10 V system integration
Full protection: Overvoltage/undervoltage/overcurrent/short‑circuit/overheating/feedback loss
Torque/speed/position control modes
Modular design for maintenance and expansion
Application Scenarios
Medium‑load CNC axes (digital encoders + analog command)
Printing/packaging/textile machinery (analog host control)
Automated assembly lines, gantries, conveyors
DIAX02 system upgrades (50 A, digital feedback, analog interface)
Space‑constrained cabinets without external cooling
Usage and Maintenance
Ensure cabinet airflow for cooling efficiency
Ambient temperature ≤45 °C to avoid derating
Complete power/feedback/control wiring before power‑on
Parameterize via IndraWorks; order and install firmware in U5
Clean heat sinks/air passages every 6 months; check terminals
Calibrate loops/encoder signals annually