Bosch Rexroth DDS03.2-W015-B Digital Servo Drive
Description
Model Definition
DDS03.2: DIAX03 system servo drive series (firmware v3.x)
W: Internal cabinet air cooling
015: 15 A continuous current rating
B: Basic unit (no pre-installed communication module; slots for option cards)
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (powered by TVD/TVM supplies)
Control supply: 24 V DC (20–28 V DC)
Continuous output current: 15 A
Peak output current: 30 A (short-term)
Current loop: 125 μs
Speed loop: 500 μs
Position loop: 2 ms
Power dissipation: ~100 W (@15 A)
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal air blower + heatsink
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 interface (digital servo encoder + resolver compatible)
System bus: Shared 300 V DC bus for multi-axis connection
Communication: Basic unit (slot U1 for fieldbus/analog modules; U5 for firmware)
Digital I/O: 6 inputs / 3 outputs (isolated, basic control signals)
Service port: RS232 (IndraWorks setup/diagnostics)
Expansion slots: U1–U5 (U1: comms; U5: firmware; U2–U4: I/O/option cards)
Core Functions
Three-loop control (current/speed/position) for precision motion
Basic unit design: flexible for custom interface upgrades (analog, SERCOS, PROFIBUS)
Internal cooling saves cabinet space for dense multi-axis layouts
Comprehensive protection: over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque/speed/position control modes
Modular firmware/software: stored on U5 module for easy replacement
Application Scenarios
Low-to-medium power CNC machine axes
Textile, printing, packaging machinery
Multi-axis handling robots and assembly lines
General-purpose automation with resolver/digital feedback
Retrofits of legacy DIAX02 systems to DIAX03 firmware
Usage and Maintenance
Ensure unobstructed cabinet airflow for cooling efficiency
Keep ambient temperature ≤45 °C to avoid performance derating
Complete power, feedback, and control wiring before power-on
Configure parameters via IndraWorks according to application requirements
Clean air ducts and heatsinks every 6 months; inspect terminal connections
Calibrate control loops and feedback signals annually