Bosch Rexroth DDS03.1-W050-DA02-00 Digital Servo Drive
Description
Model Definition
DDS03.1: DIAX02 system servo drive series
W: Internal cabinet air cooling
050: 50 A peak, 20 A continuous current rating
DA02: Analog interface module (enhanced ±10 V, with additional I/O)
00: Hardware revision 00
Technical Specifications
Electrical Parameters
DC bus voltage: 300 V DC ±15% (from TVD/TVM power supplies)
Control supply: 24 V DC (20–28 V DC)
Continuous output current: 20 A
Peak output current: 50 A (short‑term)
Current loop: 125 μs
Speed loop: 500 μs
Position loop: 2 ms
Power dissipation: ~140 W (@20 A)
Efficiency: Up to 95%
Compatible motors: MDD/MKD synchronous, LAR/LAF linear, 2AD series
Mechanical & Environmental
Cooling: Internal air blower + heatsink
Protection class: IP20 (front), IP10 (overall)
Operating temperature: 0 °C to +45 °C (20% derating @55 °C)
Storage temperature: -30 °C to +85 °C
Max altitude: 1000 m (35% derating above)
Dimensions (W×H×D): 60 mm × 408 mm × 180 mm
Weight: ~5.5 kg
Interface and Communication Configuration
Motor feedback: X4 interface for digital servo feedback
System bus: Shared 300 V DC bus (multi‑axis)
Communication: DA02 analog module (±10 V speed/torque, enhanced I/O)
Digital I/O: 8 inputs / 4 outputs (enable, fault, limits, ready)
Service port: RS232 (IndraWorks setup/diagnostics)
Configuration slots: U1–U5 for option modules
Core Functions
Three‑loop control (current/speed/position) for high precision
DA02 enhanced analog interface: improved noise immunity, extra I/O vs DA01
Internal cooling saves cabinet space for dense multi‑axis layouts
Comprehensive protection: over/undervoltage, overcurrent, short circuit, overheat, feedback loss
Torque / speed / position control modes
Modular design: fieldbus/serial modules can be retrofitted
Application Scenarios
Medium‑to‑high power CNC machine axes
Textile, printing, packaging machinery
Multi‑axis handling robots and assembly lines
Analog‑based automation systems needing extra I/O
Retrofits of legacy analog servo systems
Usage and Maintenance
Ensure adequate cabinet airflow for cooling
Keep ambient ≤45 °C to avoid derating
Complete power/feedback/analog wiring before power‑on
Set parameters via IndraWorks according to application
Clean air ducts/heatsinks every 6 months; check terminals
Calibrate loops/feedback annually