Leistritz DDS02.1-A100-D Digital Servo Drive
Description
Model Explanation
DDS02.1: DIAX02 system, driver series 02.1 (version 2.1, 2nd generation)
A: External air cooling (heat sink outside the cabinet)
100: Rated continuous current 100 A
D: Basic configuration (default DSF digital feedback, no pre-installed communication card, U1 slot empty or standard card)
Technical Parameters
Electrical Parameters
DC bus: 300 V DC ±15% (TVD/TVM power supply)
Control power supply: 24 V DC (20–28 V)
Continuous current: 100 A
Peak current: 200 A (short time)
Control cycle: Current loop ≈ 62.5 μs, speed loop ≈ 250 μs
Feedback: DSF digital servo feedback (standard)
Mechanical and Environmental
Cooling method: External air cooling (A)
Protection level: IP20
Operating temperature: 0 to +45 ℃ (55 ℃ is allowable)
Storage temperature: -30 to +85 ℃
Weight: Approximately 16 kg
Interface and Communication Configuration
Control interface: No pre-installed bus card (U1 slot can be inserted with SERCOS, PROFIBUS, etc.)
Feedback interface: DSF digital servo feedback (motor end)
Bus: Shared 300 V DC bus for all axes
I/O: Digital input/output, enable, alarm, limit
Expansion: U2–U4 slots can be inserted with communication / feedback modules Core function
Full closed-loop control: three loops of current / speed / position, with fast dynamic response and high positioning accuracy
Digital feedback: DSF has strong anti-interference ability, high resolution, and is suitable for high-speed motors
Modular expansion: communication / feedback cards are plug-and-play, allowing flexible configuration of multi-axis systems
Comprehensive protection: overvoltage, undervoltage, short circuit, overheating, and open circuit protection
Basic motion functions: point position, speed, and torque control, suitable for general automation scenarios Applicable scenarios
Machine tools: Large CNC, gantry machines, heavy-duty lathes, five-axis machining centers
Automation: Multi-axis synchronous production lines, robots, injection molding machines, tension control equipment
Testing: High-precision test benches, dynamic simulation equipment, fatigue testing systems
Packaging / Printing: High-speed offset printing, synchronous cutting, tension control, multi-axis linkage equipment Use and Maintenance
Installation: Vertical installation, with unobstructed external air duct and away from heat sources
Heat dissipation: Ambient temperature ≤ 45 ℃, altitude ≤ 1000 m
Commissioning: 300 V DC, 24 V DC, motor DSF feedback; Parametric IndraWorks software
Maintenance: Clean and inspect terminals every 6 months; Calibrate current loop and position loop annually
Get a Quote