Leistec DDS02.1-A050-DS01-02 Digital Servo Drive
Description
Model Explanation
DDS02.1: DIAX02 system, driver series 02.1 (version 2.0)
A: External air cooling (heat sink outside the cabinet)
050: Rated continuous current 50 A
DS01: SERCOS optical bus interface + DSF digital servo feedback (slot U1)
02: Hardware version 2
Technical Parameters
Electrical Parameters
DC bus: 300 V DC ±15% (supplied by TVD/TVM power supply)
Control power supply: 24 V DC (20–28 V)
Continuous current: 50 A
Peak current: 100 A (short-term)
Control cycle: Current loop ≈ 62.5 μs, speed loop ≈ 250 μs
Feedback: DSF digital servo feedback (standard)
Mechanical and Environmental
Cooling method: External air cooling (A)
Protection level: IP20
Operating temperature: 0 to +45 ℃ (55 ℃ is allowable)
Storage temperature: -30 to +85 ℃
Weight: Approximately 11 kg
Interface and Communication Configuration
Control interface: SERCOS optical high-speed bus (DS01)
Feedback interface: DSF digital servo feedback (motor end)
Bus: Shared 300 V DC bus for all axes
I/O: Digital input/output, enable, alarm, limit
Expansion: U2–U4 slots can be inserted with PROFIBUS, analog quantities, etc. modules Core function
SERCOS Real-time Bus: Multi-axis synchronization, high-speed and high-precision motion control
Full closed-loop control: Current/Speed/Position three-loop, fast dynamic response
Digital feedback: DSF has strong anti-interference ability and high resolution
Modular expansion: Communication/Feedback cards are plug-and-play, flexible configuration
Comprehensive protection: Overvoltage, undervoltage, short circuit, overheating, open circuit protection Applicable scenarios
Machine tools: High-speed CNC, machining centers, gantry machines
Automation: Multi-axis synchronous production lines, robots, injection molding machines
Testing: High-precision test benches, dynamic simulation equipment
Packaging / Printing: High-speed offset printing, tension control, synchronous cutting Use and Maintenance
Installation: Vertical installation, with unobstructed external air duct and away from heat sources
Heat dissipation: Ambient temperature ≤ 45 ℃, altitude ≤ 1000 m
Commissioning: 300 V DC, 24 V DC, motor DSF feedback, SERCOS bus; Parametric IndraWorks software
Maintenance: Clean and inspect terminals every 6 months; Calibrate current loop and position loop annually
Get a Quote