8280-423
Description
Key Features
High‑voltage wide‑range DC input: 90–150 VDC (nominal 125 VDC)
Dual redundant magnetic pickup (MPU) speed inputs for high‑reliability speed detection
Built‑in DSLC real‑kW load‑sharing for multi‑genset parallel operation
Single LON bus for DSLC network communication; RS‑232/422/485 with Modbus RTU/ASCII
Isochronous (constant‑speed) & droop control modes, overspeed protection, startup fuel limit, self‑diagnostics
Conformal‑coated PCB, anti‑vibration & EMI‑resistant, marine‑qualified
Electrical Specifications
Power Supply: 90–150 VDC
Power Consumption: 40 W
Inrush Current: 22 A @ 15 ms
Speed Input: 2‑channel MPU, 400 Hz–15 kHz
Communication: Single LON bus, RS‑232/422/485, Modbus RTU/ASCII
Operating Temperature: −40 °C ~ +70 °C
Certifications: CE, UL, Class I Div 2 hazardous area compliant, Lloyd’s Register marine certified
Mechanical & Environmental Features
Mounting: Front panel‑mount
Housing: Rugged metal enclosure
Dimensions: 412.8 × 292.1 × 60.4 mm
Weight: ~2.8 kg
Low‑voltage equivalent: 8280‑422 (18–40 VDC)
Typical Applications
Small‑scale multi‑generator parallel power stations
Marine auxiliary engine speed & load control
Offshore oil‑gas small‑unit power system governing
Industrial heavy‑duty standby genset parallel control
Get a Quote