Dual speed control modes: isochronous (constant‑speed) for single‑unit operation; droop control for parallel gensets.
Real kW‑based load sharing, ensuring balanced power output among multiple paralleled generator sets.
Built‑in overspeed protection, startup ramp, actuator stroke limit and torque limiting functions.
Supports idle‑rated speed switching, 4‑20 mA remote setpoint input for DCS/PLC speed adjustment.
Forward‑acting control logic, compatible with standard proportional electric/hydraulic actuators.
Electrical Specifications
Power Supply: 18–40 VDC (nominal 24 VDC)
Speed Input: Magnetic pickup (MPU)
Actuator Output: 0–200 mA proportional current
Communication: RS‑485 Modbus‑RTU
Operating Temperature: −40 °C ~ +85 °C
Certifications: CE, Class 1 Div 2 hazardous area compliant
Environmental & Mechanical Features
Mounting: Front panel‑mount
Enclosure: Rugged metal housing, dust‑proof, vibration‑resistant
High reliability for 24‑hour continuous industrial operation
Typical Applications
Multi‑genset parallel power control for diesel/gas engine power stations
Marine power plant prime‑mover speed & load regulation
Oil‑gas industrial backup generator set control systems
Off‑grid power generation and distributed energy control