8516-042
Description
Core Functions
Precise mechanical‑hydraulic closed‑loop speed control for stable prime‑mover operation
Supports isochronous (zero‑droop) for standalone units and droop control for parallel‑running gensets/turbines
Built‑in overspeed protection, speed limit adjustment and start‑up fuel limiting
Speed/load setpoint via 4‑20 mA or 1‑5 Vdc analog input for remote control
Compatible with Woodward electronic controllers for integrated system regulation
Rugged oil‑relay design for high‑temperature, high‑vibration harsh environments
Technical Specifications
Power/Actuation: Hydraulic oil‑pressure driven governor assembly
Speed Regulation Mode: Isochronous / Droop (adjustable)
Analog Input: 4‑20 mA, 1‑5 Vdc for remote speed/load setting
Operating Temperature: −40 °C ~ +70 °C
Rotation Direction: CCW (counter‑clockwise) standard
Mounting: Flange‑mount for turbine/engine integration
Construction: Heavy‑duty metal housing, oil‑sealed, shock‑resistant
Typical Applications
Steam & gas turbine power plants
Marine propulsion and auxiliary power turbines
Oilfield, refinery and mining turbine‑driven equipment
Industrial generator sets and critical continuous‑run power systems