DDC01.2-N100A-DA02-01
Description
Model Analysis
DDC01.2: DDC series, hardware version 1.2
N100A: 3 × 220–230V, air cooling, 100A peak / 35A continuous
DA02: Enhanced analog interface command module (U1 slot)
01: Function code 01, version 01
(No FW): Firmware (e.g. FWC-DSM2.1) needs to be ordered separately
Core Parameters
Input: Three-phase AC220/230V ±10%, 50/60Hz
Output: 35A continuous / 100A peak; 6kW continuous / 17kW peak
Protection: IP65 (dust and water spray protection)
Cooling: Forced air cooling, heat dissipation 500W
Brake resistor: Continuous 0.25kW / Peak 20kW
PWM frequency: 4kHz
Weight: Approximately 22kg
Size: 517 × 165 × 298 mm
DA02 Module Interface (Enhanced Analog Type)
Command: ±10V analog quantity (speed / torque, higher resolution)
Feedback: Digital servo encoder (compatible with MDD motor)
I/O: 8DI/8DO (24VDC); RS232 (X2) debugging port
Enhancements: Compared to DA01, it has additional analog filtering and fault locking functions Main function
Three-loop control: position (analog setpoint), speed, torque
Integrated braking unit; LED status self-diagnosis
Power-off parameter retention; shock-resistant structure can be directly installed Application scenario
High-load single-axis for machines, packaging, printing, etc.
Heavy-duty conveyors, mechanical hands, DDC series renovation and replacement
Maintenance points
Regularly clean the fan / heat dissipation fins; check the IP65 seal
RS232 + DDS2PC debugging; firmware ordered separately