DDC01.2-N050C-DL01-01
Description
I. Product Introduction
DDC01.2-N050C-DL01-01 is a DDC series digital intelligent servo drive from the Indramat brand under the Bosch Rexroth company. It is a single-axis compact controller that is compatible with the MDD series AC servo motors and is used in high-precision servo control scenarios.
II. Technical Specifications
Electrical Parameters
Rated Current: 50A
Peak Current: 50A
Continuous Current: 25A
Short-time Current (S6-100s, 50% Load): 50A
PWM Frequency: 8kHz
Input Power Supply: 3×220V AC (±15%/-10%), 50/60Hz
Rated Power: 4kW (Continuous), 8.5kW (Peak)
Mechanical and Environmental
Protection Grade: IP65
Operating Temperature: +5℃~+45℃ (Rated), Maximum + 55℃ (Degrading)
Storage Temperature: -30℃~+85℃
Relative Humidity: ≤95% (No Condensation)
Weight: 21kg
Installation Altitude: ≤1000m (No Degradation)
Functional Features
Integrated Shunt Resistor and DC Bus Converter, compatible with Braking Energy Recovery
Digital Servo Feedback, High-Resolution Rotor Position Measurement
Panel Includes S1 Fault Reset Button and H1 LED Status Indicator Light
Support for Direct Installation in Harsh Operating Conditions such as Feeders
III. Operating Instructions
Installation and Wiring
Environmental Requirements: Flat installation surface, shockproof, away from heat sources and corrosive gases; ensure good ventilation.
Electrical Connections:
Power Supply: 3×AC 220V connected to the main power terminal, equipped with slow-melting gL type fuse or circuit breaker.
Motor: Connect MDD series motor power line and feedback line to ensure IP65 protection seal.
Control: X2 port (RS232) connected to PC for parameter configuration and diagnosis (DDS2PC software).
Debugging and Operation
Before Power On: Verify that the model and configuration nameplate are consistent, and there is no short circuit / open circuit in the wiring.
Parameter Configuration: Set motor parameters, position / speed / current loop parameters through DDS2PC software.
Operating Modes: Support positioning, speed, torque modes; In point motion mode, manual movement of the axis and reference point calibration are possible.
Fault Handling: LED indicator lights display fault codes, common overcurrent, overvoltage, overheating, communication abnormalities; Troubleshoot through the Fault Report Manual.
Maintenance Points
Regularly clean the heat dissipation channels to avoid dust accumulation.
Check the tightness of wiring terminals to prevent vibration loosening.
Avoid frequent start-stop and overloading operation to extend service life