DDC01.2-N050C-DL01-01
May 26, 2026

DDC01.2-N050C-DL01-01

Model Analysis DDC01.2: Series and Version (DDC Series, Version 1.2) N050C: Rated Current 50A, Cooling Method: Air Cooling DL01-01: Control Module and Function Code (Single-axis Positioning Control, Function Code 01)

Description

I. Product Introduction

DDC01.2-N050C-DL01-01 is a DDC series digital intelligent servo drive from the Indramat brand under the Bosch Rexroth company. It is a single-axis compact controller that is compatible with the MDD series AC servo motors and is used in high-precision servo control scenarios.

II. Technical Specifications

Electrical Parameters

Rated Current: 50A

Peak Current: 50A

Continuous Current: 25A

Short-time Current (S6-100s, 50% Load): 50A

PWM Frequency: 8kHz

Input Power Supply: 3×220V AC (±15%/-10%), 50/60Hz

Rated Power: 4kW (Continuous), 8.5kW (Peak)

Mechanical and Environmental

Protection Grade: IP65

Operating Temperature: +5℃~+45℃ (Rated), Maximum + 55℃ (Degrading)

Storage Temperature: -30℃~+85℃

Relative Humidity: ≤95% (No Condensation)

Weight: 21kg

Installation Altitude: ≤1000m (No Degradation)

Functional Features

Integrated Shunt Resistor and DC Bus Converter, compatible with Braking Energy Recovery

Digital Servo Feedback, High-Resolution Rotor Position Measurement

Panel Includes S1 Fault Reset Button and H1 LED Status Indicator Light

Support for Direct Installation in Harsh Operating Conditions such as Feeders

III. Operating Instructions

Installation and Wiring

Environmental Requirements: Flat installation surface, shockproof, away from heat sources and corrosive gases; ensure good ventilation.

Electrical Connections:

Power Supply: 3×AC 220V connected to the main power terminal, equipped with slow-melting gL type fuse or circuit breaker.

Motor: Connect MDD series motor power line and feedback line to ensure IP65 protection seal.

Control: X2 port (RS232) connected to PC for parameter configuration and diagnosis (DDS2PC software).

Debugging and Operation

Before Power On: Verify that the model and configuration nameplate are consistent, and there is no short circuit / open circuit in the wiring.

Parameter Configuration: Set motor parameters, position / speed / current loop parameters through DDS2PC software.

Operating Modes: Support positioning, speed, torque modes; In point motion mode, manual movement of the axis and reference point calibration are possible.

Fault Handling: LED indicator lights display fault codes, common overcurrent, overvoltage, overheating, communication abnormalities; Troubleshoot through the Fault Report Manual.

Maintenance Points

Regularly clean the heat dissipation channels to avoid dust accumulation.

Check the tightness of wiring terminals to prevent vibration loosening.

Avoid frequent start-stop and overloading operation to extend service life


Get a Quote