DDC01.2-K150A-D
Description
1. Model Disassembly (DDC01.2-K150A-D)
DDC: Digital Drive Controller (Digital Drive Controller)
01.2: The 1st generation, Hardware Version 2 (Optimized for heat dissipation/EMI, more stable than 01.1)
K150A: K = Forced air cooling; 150 = 150A continuous; A = Standard noise
D: Digital Feedback (Digital Feedback) (MDD/MKD motor encoders)
⚠️ Missing section: -DAxx/DLxx/DSxx (Command Interface) and - 00/01 (Hardware Revision), -FW (Firmware)
2. Core Electrical Parameters
Input: 3×AC 380–460V (Commonly used in industry), 50/60Hz
Control Power Supply: 24VDC
Continuous Output: 150A; Peak: 300A (1s)
DC Bus: ≈700VDC
Switching Frequency: 4kHz
Protection: STO, Overcurrent / Overvoltage / Overheat / Phase Missing
3. Mechanical and Environmental
Size (H×W×D): ≈360×280×260 mm
Weight: ≈24 kg
Protection: IP65 (Dust and Waterproof)
Operating Temperature: +5°C~+45°C (Full load)
Cooling: K = Fan forced air cooling (Suitable for continuous high load)
4. Control and Interface (D = Digital Feedback)
Feedback: Digital Servo (MDD/MKD, multi-turn encoders)
Command Interface: Not labeled (Full model requires DA/DL/DS section)
DA = Pure analog ±10V
DL = DLC bus + analog
DS = SERCOS digital bus
Communication: RS-232/485 (Diagnosis / Parameters)
5. Common Complete Models (Reference for Completion)
DDC01.2-K150A-DA02-01: 150A, Forced air cooling, Enhanced analog quantity
DDC01.2-K150A-DL01-01-FW: 150A, Forced air cooling, DLC + analog, Firmware
DDC01.2-K150A-DS03-02-FW: 150A, Forced air cooling, SERCOS bus
6. Compatible Motors
MDD: MDD093A, MDD112A, MDD132A (150A framework)
MKD: MKD090B, MKD112B, MKD132B
7. Comparison with K100A/K200A
K100A: 100A continuous, Medium power
K150A: 150A continuous, Medium-large power (This model)
K200A: 200A continuous, Large power
8. Application Scenarios
Medium-large power (150A) single-axis control
Machine tool spindle, large lathes, extruders, injection molding machines
Requires continuous high load, strong heat dissipation in industrial environments