DDC01.2-K100A-DA02-01
Description
1. Model Disassembly (DDC01.2-K100A-DA02-01)
DDC: Digital Drive Controller (Digital Drive Controller)
01.2: The 1st generation, Hardware Version 2 (Optimized for heat dissipation and circuit compared to 01.1)
K100A: K = Forced air cooling; 100 = 100A continuous; A = Standard noise
DA02: D = Digital feedback; A = Pure analog quantity (±10V); 02 = Enhanced analog quantity (More functions than 01)
01: Hardware Revision 1 (Bug fixes, Better compatibility)
2. Key Technical Parameters Electrical
Input: 3×AC 380–460V, 50/60Hz
Control power supply: 24VDC
Continuous output: 100A; Peak: 200A (1s)
DC bus: ≈700VDC
Switching frequency: 4kHz
Mechanical and environmental
Dimensions (H×W×D): ≈360×225×260mm
Weight: ≈21kg
Protection: IP65
Operating temperature: +5°C~+45°C (full load)
Cooling: K = Fan forced air cooling (strong cooling, suitable for continuous high load)
Control and interface
Control mode: Speed / Torque (Enhanced Analog ±10V); No built-in positioning
Feedback: Digital servo (MDD/MKD, multi-turn encoder)
Command: Only analog ±10V (Enhanced version, with better bandwidth and precision than DA01)
Communication: RS-232/485 (diagnosis, parameter setting)
Safety: STO, Overcurrent, Overvoltage, Overheat, Phase Missing Protection
3.01.2 Core Differences between 01.2 and 01.1
01.2 (This model):
Optimized air duct and fan, improved heat dissipation efficiency
Enhanced circuit anti-interference, better EMI performance
Supports higher ambient temperature and longer full load time
01.1: Basic hardware, slightly weaker cooling and stability
4. DA02 and DA01 Differences (Analog version)
DA01: Basic analog, standard bandwidth, simple diagnosis
DA02 (This model): Enhanced analog
Higher response bandwidth (Speed loop bandwidth ↑30%)
More precise torque control, smaller speed fluctuation at low speed
Extended diagnosis (Current / Voltage / Temperature monitoring more detailed)
Suitable for more motor models
5. Compatible Motors
MDD series: MDD071A, MDD093A, MDD112A (100A framework)
MKD series: MKD071B, MKD090B, MKD112B
6. Application Scenarios
Medium and large power (100A) single-axis analog control
Equipment requiring high response and high precision speed / torque control
Machine tools, injection molding machines, extruders, packaging machinery
Upper computer (PLC/NC) systems only providing ±10V commands
Get a Quote