CSB01.1N-SE-ENS-NNN-NN-S-NN-FW
May 26, 2026

CSB01.1N-SE-ENS-NNN-NN-S-NN-FW

CSB01.1N-SE-ENS-NNN-NN-S-NN-FW Brand: Bosch Rexroth Part Number: R911305276 Position: Basic fixed single-axis servo control card, SERCOS optical bus, single encoder, no safety function, standard panel, pre-installed firmware, no expansion slots, compatible with HCS series power units.

Description

Model Explanation

CSB01.1N: CSB01 series, V01.1, N = Fixed Standard Version, No Expansion Slot

SE: SERCOS II Fiber Bus, Strong Anti-interference, Suitable for Long-distance / High-speed Multi-axis Synchronization

ENS: Motor Master Encoder Interface (12V), Compatible with Hiperface, 1Vpp, TTL, IndraDyn Encoder

NNN: No Second Encoder, Analog Input, Encoder Simulation, etc. Expansion Interfaces

NN: No STO/SS1 Integrated Safety Circuit

S: Single-line LED + 4 Buttons Local Operation Panel

NN: No Extra Special Function Modules

FW: Factory Pre-installed Firmware, Plug-and-Play

Core Parameters

Number of Controlled Axes: Single Axis

Power Supply: DC24V ±10%, Power Consumption Approximately 8W

Control Cycle: Current Loop 125μs, Speed Loop 250μs, Position Loop 500μs

Interfaces: Fiber SERCOS, RS232 Debug Port, Ethernet Service Port; 5DI / 3DI/O / 1 Relay Output

Protection: IP20 (Installed in Cabinet)

Size / Weight: 103×241×103mm, Approximately 0.8kg

Compatible Units: HCS01/HCS02/HCS03

Compatible Motors: MSK, MHD, MKE Full Series IndraDyn Servo Motors

Comparison with SE Models of the Same Series Table

Full model Safety configuration Grade Applicable scenarios

CSB01.1N-SE-ENS-NNN-NN-S-NN-FW No safety - General equipment, no safety regulations required

CSB01.1N-SE-ENS-NNN-L1-S-NN-FW STO SIL2/PLd Basic safety condition

CSB01.1N-SE-ENS-NNN-L2-S-NN-FW STO SIL3/PLe High safety, high-risk equipment Application scenario

Suitable for CNC machines, printing, textile, and high-speed multi-axis coordinated production lines based on SERCOS optical fiber bus architecture; suitable for standardized single-axis servo systems with high electromagnetic interference, long wiring distance, and no need for safety shutdown function, serving as standard economical spare parts for this bus specification.