171CCS78000
Description
1. General Description
2. Product Identification
Model: 171CCS78000
Manufacturer: Schneider Electric
Series: Modicon Momentum
Type: M1/M1E Processor Adapter (RS‑232 + isolated RS‑485, 20 MHz, LL984 only)
Compatibility: All Modicon Momentum I/O bases (170XTS series)
Status: Discontinued (spare parts only)
Country of Origin: France
Certifications: CE, UL, cUL, FM Class 1 Div 2, NEMA 250
3. Technical Specifications
Processor & Memory
CPU: 20 MHz proprietary
Flash: 256 KB (program storage)
RAM: 64 KB (data + program execution)
Program Memory (LL984): 2.4 K words
Data Memory: 64 KB
Scan Time: 1.0 ms per KB
Word Length: 16‑bit
I/O Capacity
Discrete I/O: 2048 inputs / 2048 outputs
Register I/O: 2048 words in / 2048 words out
Communication Ports
Port 1 – RS‑232 (non‑isolated): DB9, Modbus RTU/ASCII slave, up to 19.2 kbps
Port 2 – RS‑485 (isolated): Terminal block, Modbus RTU/ASCII master/slave, up to 19.2 kbps
Diagnostic LEDs: PWR (green), RUN (green), FLT (red), COMM1 (yellow), COMM2 (yellow)
Electrical
Supply Voltage: 5 V DC ±5% (from Momentum I/O base)
Power Consumption: ≤ 8 W
Environmental
Operating Temperature: 0 °C to +40 °C (non‑condensing)
Storage Temperature: −40 °C to +85 °C
Humidity: 5–95% RH (non‑condensing)
Vibration: 0.75 mm displacement, 1 g acceleration
Shock: 15 g peak, 11 ms duration
Altitude: Up to 2000 m (no derating)
Physical
Dimensions (H × W × D): 25 mm × 125 mm × 183 mm
Weight: 0.042 kg (0.09 lbs)
Material: Lexan (industrial polycarbonate), conformal coating
4. Key Features
Dual Independent Serial Ports: RS‑232 (slave) + isolated RS‑485 (master/slave)
20 MHz CPU: Reliable performance for LL984 logic
64 KB RAM / 256 KB Flash: Ample memory for small‑to‑medium programs
Isolated RS‑485: Noise immunity for long‑distance Modbus networks
LL984 Only: Optimized for legacy Modicon programming
Drop‑In Fit: Compatible with all 170XTS I/O bases
5. Applications
Small‑to‑medium standalone PLC control with Momentum I/O
OEM machinery (conveyors, packaging, assembly lines)
Systems requiring two Modbus ports (e.g., HMI on RS‑232, remote I/O on RS‑485)
Legacy LL984 installations needing dual serial communication
Retrofit projects replacing older Modicon controllers
Industrial environments requiring isolated serial communication
6. Installation Instructions
Power Off: Disconnect power to the Momentum I/O base.
ESD Protection: Use anti‑static wristband when handling.
Mounting: Align adapter with I/O base connector; press firmly until seated. Tighten screws.
RS‑232 Wiring: Connect DB9 cable to HMI/SCADA; configure baud rate, data bits, parity, stop bits.
RS‑485 Wiring: Connect to Modbus network (+/−, GND); configure baud rate, parity, master/slave address.
Power Up: Apply 5 V DC. Check LEDs: PWR ON, RUN blinking (program execution), COMM1/COMM2 blinking (activity).
Programming: Download LL984 program via Modsoft ≥ V2.5 or ProWORX 32.
7. Compatibility
I/O Bases: All 170XTS series discrete/analog I/O bases
Software: LL984 only (Modsoft, ProWORX 32)
Network: Modbus RTU/ASCII (RS‑232 slave; RS‑485 master/slave)
Replacement: Superseded by 171CCC98030 (Ethernet + dual RS‑485, IEC 61131‑3 + LL984)
8. Safety & Handling
Installation/maintenance by qualified personnel per local codes.
Disconnect power before wiring/service to avoid electric shock.
Avoid water, moisture, corrosive substances, direct sunlight.
Use ESD protection to prevent static damage.
Do not open casing; no user‑serviceable parts inside.
9. Maintenance & Troubleshooting
Inspection: Quarterly check for cracks, loose screws, damaged connectors, LED status.
Cleaning: Dry, lint‑free cloth only; no solvents/abrasives.
Common Issues:
PWR Off: Check 5 V DC supply from I/O base.
FLT On: CPU fault; re‑seat adapter, reload program, check I/O base.
COMM1 No Response: Verify RS‑232 wiring, baud rate, parity, slave address.
COMM2 No Response: Verify RS‑485 wiring, baud rate, parity, master/slave address, termination.
No Program Execution: Ensure program downloaded, RUN mode active, no fatal faults.
10. Replacement Information
171CCC98030: Ethernet + dual RS‑485, IEC 61131‑3 + LL984, 1 MB Flash, 0–60 °C