171CCS78000
May 23, 2026

171CCS78000

The 171CCS78000 is a compact, dual‑port M1/M1E processor adapter for Schneider Electric Modicon Momentum I/O bases, converting them into standalone PLCs. It features a 20 MHz CPU, one RS‑232 and one isolated RS‑485 Modbus port, 64 KB RAM, 256 KB Flash, and supports LL984 programming only. Designed for small‑to‑medium industrial control requiring two independent serial communication links.

Description

1. General Description

The 171CCS78000 is a compact, dual‑port M1/M1E processor adapter for Schneider Electric Modicon Momentum I/O bases, converting them into standalone PLCs. It features a 20 MHz CPU, one RS‑232 and one isolated RS‑485 Modbus port, 64 KB RAM, 256 KB Flash, and supports LL984 programming only. Designed for small‑to‑medium industrial control requiring two independent serial communication links.

2. Product Identification

  • Model: 171CCS78000

  • Manufacturer: Schneider Electric

  • Series: Modicon Momentum

  • Type: M1/M1E Processor Adapter (RS‑232 + isolated RS‑485, 20 MHz, LL984 only)

  • Compatibility: All Modicon Momentum I/O bases (170XTS series)

  • Status: Discontinued (spare parts only)

  • Country of Origin: France

  • Certifications: CE, UL, cUL, FM Class 1 Div 2, NEMA 250

3. Technical Specifications

Processor & Memory

  • CPU: 20 MHz proprietary

  • Flash: 256 KB (program storage)

  • RAM: 64 KB (data + program execution)

  • Program Memory (LL984): 2.4 K words

  • Data Memory: 64 KB

  • Scan Time: 1.0 ms per KB

  • Word Length: 16‑bit

I/O Capacity

  • Discrete I/O: 2048 inputs / 2048 outputs

  • Register I/O: 2048 words in / 2048 words out

Communication Ports

  • Port 1 – RS‑232 (non‑isolated): DB9, Modbus RTU/ASCII slave, up to 19.2 kbps

  • Port 2 – RS‑485 (isolated): Terminal block, Modbus RTU/ASCII master/slave, up to 19.2 kbps

  • Diagnostic LEDs: PWR (green), RUN (green), FLT (red), COMM1 (yellow), COMM2 (yellow)

Electrical

  • Supply Voltage: 5 V DC ±5% (from Momentum I/O base)

  • Power Consumption: ≤ 8 W

Environmental

  • Operating Temperature: 0 °C to +40 °C (non‑condensing)

  • Storage Temperature: −40 °C to +85 °C

  • Humidity: 5–95% RH (non‑condensing)

  • Vibration: 0.75 mm displacement, 1 g acceleration

  • Shock: 15 g peak, 11 ms duration

  • Altitude: Up to 2000 m (no derating)

Physical

  • Dimensions (H × W × D): 25 mm × 125 mm × 183 mm

  • Weight: 0.042 kg (0.09 lbs)

  • Material: Lexan (industrial polycarbonate), conformal coating

4. Key Features

  • Dual Independent Serial Ports: RS‑232 (slave) + isolated RS‑485 (master/slave)

  • 20 MHz CPU: Reliable performance for LL984 logic

  • 64 KB RAM / 256 KB Flash: Ample memory for small‑to‑medium programs

  • Isolated RS‑485: Noise immunity for long‑distance Modbus networks

  • LL984 Only: Optimized for legacy Modicon programming

  • Drop‑In Fit: Compatible with all 170XTS I/O bases

5. Applications

  • Small‑to‑medium standalone PLC control with Momentum I/O

  • OEM machinery (conveyors, packaging, assembly lines)

  • Systems requiring two Modbus ports (e.g., HMI on RS‑232, remote I/O on RS‑485)

  • Legacy LL984 installations needing dual serial communication

  • Retrofit projects replacing older Modicon controllers

  • Industrial environments requiring isolated serial communication

6. Installation Instructions

  1. Power Off: Disconnect power to the Momentum I/O base.

  2. ESD Protection: Use anti‑static wristband when handling.

  3. Mounting: Align adapter with I/O base connector; press firmly until seated. Tighten screws.

  4. RS‑232 Wiring: Connect DB9 cable to HMI/SCADA; configure baud rate, data bits, parity, stop bits.

  5. RS‑485 Wiring: Connect to Modbus network (+/−, GND); configure baud rate, parity, master/slave address.

  6. Power Up: Apply 5 V DC. Check LEDs: PWR ON, RUN blinking (program execution), COMM1/COMM2 blinking (activity).

  7. Programming: Download LL984 program via Modsoft ≥ V2.5 or ProWORX 32.

7. Compatibility

  • I/O Bases: All 170XTS series discrete/analog I/O bases

  • Software: LL984 only (Modsoft, ProWORX 32)

  • Network: Modbus RTU/ASCII (RS‑232 slave; RS‑485 master/slave)

  • Replacement: Superseded by 171CCC98030 (Ethernet + dual RS‑485, IEC 61131‑3 + LL984)

8. Safety & Handling

  • Installation/maintenance by qualified personnel per local codes.

  • Disconnect power before wiring/service to avoid electric shock.

  • Avoid water, moisture, corrosive substances, direct sunlight.

  • Use ESD protection to prevent static damage.

  • Do not open casing; no user‑serviceable parts inside.

9. Maintenance & Troubleshooting

  • Inspection: Quarterly check for cracks, loose screws, damaged connectors, LED status.

  • Cleaning: Dry, lint‑free cloth only; no solvents/abrasives.

  • Common Issues:

    • PWR Off: Check 5 V DC supply from I/O base.

    • FLT On: CPU fault; re‑seat adapter, reload program, check I/O base.

    • COMM1 No Response: Verify RS‑232 wiring, baud rate, parity, slave address.

    • COMM2 No Response: Verify RS‑485 wiring, baud rate, parity, master/slave address, termination.

    • No Program Execution: Ensure program downloaded, RUN mode active, no fatal faults.

10. Replacement Information

171CCS78000 is discontinued. Recommended replacement:
  • 171CCC98030: Ethernet + dual RS‑485, IEC 61131‑3 + LL984, 1 MB Flash, 0–60 °C


Get a Quote