The 171CCS70010 is a compact, high‑performance M1 processor adapter for Schneider Electric Modicon Momentum I/O bases, converting them into standalone PLCs. It features a 32 MHz CPU, non‑isolated RS‑232 serial port (Modbus RTU/ASCII slave), 64 KB RAM, and 256 KB Flash. Programmed exclusively in LL984, it is designed for small‑to‑medium industrial control applications requiring faster scan times than the 171CCS70000.

Description

1. General Description

The 171CCS70010 is a compact, high‑performance M1 processor adapter for Schneider Electric Modicon Momentum I/O bases, converting them into standalone PLCs. It features a 32 MHz CPU, non‑isolated RS‑232 serial port (Modbus RTU/ASCII slave), 64 KB RAM, and 256 KB Flash. Programmed exclusively in LL984, it is designed for small‑to‑medium industrial control applications requiring faster scan times than the 171CCS70000.

2. Product Identification

  • Model: 171CCS70010

  • Manufacturer: Schneider Electric

  • Series: Modicon Momentum

  • Type: M1 Processor Adapter (RS‑232, 32 MHz, LL984 only)

  • Compatibility: All Modicon Momentum I/O bases (170XTS series)

  • Status: Obsolete / Discontinued (spare parts only)

  • Country of Origin: France

  • Certifications: CE, UL, cUL, FM Class 1 Div 2, NEMA 250

3. Technical Specifications

Processor & Memory

  • CPU: 32 MHz proprietary

  • Flash: 256 KB (program storage)

  • RAM: 64 KB (data + program execution)

  • Program Memory (LL984): 18 KB

  • Data Memory: 24 KB

  • Scan Time: 0.63 ms per KB

  • Word Length: 16‑bit

I/O Capacity

  • Discrete I/O: 2048 inputs / 2048 outputs

  • Register I/O: 2048 words in / 2048 words out

Communication Port

  • RS‑232 (non‑isolated): DB9 connector, Modbus RTU/ASCII, slave only, up to 19.2 kbps

  • Diagnostic LEDs: PWR (green), RUN (green), FLT (red), COMM (yellow)

Electrical

  • Supply Voltage: 5 V DC ±5% (from Momentum I/O base)

  • Power Consumption: ≤ 8 W

Environmental

  • Operating Temperature: 0 °C to +40 °C (non‑condensing)

  • Storage Temperature: −40 °C to +85 °C

  • Humidity: 5–95% RH (non‑condensing)

  • Vibration: 0.75 mm displacement, 1 g acceleration

  • Shock: 15 g peak, 11 ms duration

  • Altitude: Up to 2000 m (no derating)

Physical

  • Dimensions (H × W × D): 25 mm × 125 mm × 183 mm

  • Weight: 0.042 kg (0.09 lbs)

  • Material: Lexan (industrial polycarbonate)

4. Key Features

  • 32 MHz High‑Speed CPU: Faster scan time (0.63 ms/KB) vs. 171CCS70000 (1.0 ms/KB)

  • RS‑232 Serial: Modbus RTU/ASCII slave for HMI/SCADA connection

  • Compact & Lightweight: Easy installation on Momentum I/O bases

  • Industrial Durability: Shock/vibration resistant, conformal coating

  • Drop‑In Fit: Compatible with all Momentum 170XTS I/O bases

5. Applications

  • Small‑to‑medium standalone PLC control with Momentum I/O

  • Cost‑sensitive OEM machinery (conveyors, packaging, assembly lines)

  • LL984‑based systems requiring RS‑232 Modbus slave communication

  • Retrofit projects replacing older Modicon controllers

  • Remote I/O control with serial HMI connection

6. Installation Instructions

  1. Power Off: Disconnect power to the Momentum I/O base.

  2. ESD Protection: Use anti‑static wristband when handling.

  3. Mounting: Align adapter with I/O base connector; press firmly until seated. Tighten screws.

  4. RS‑232 Wiring: Connect DB9 cable to HMI/SCADA; configure baud rate, data bits, parity, stop bits.

  5. Power Up: Apply 5 V DC. Check LEDs: PWR ON, RUN blinking (program execution), COMM blinking (activity).

  6. Programming: Download LL984 program via Concept, ProWORX 32, or Modsoft.

7. Compatibility

  • I/O Bases: All 170XTS series Momentum discrete/analog I/O bases

  • Software: LL984 only (Concept ≥ V2.1, ProWORX 32/NxT, Modsoft ≥ V2.5)

  • Network: Modbus RTU/ASCII (RS‑232 slave only)

  • Replacement: Superseded by 171CCS76000 (RS‑485) or 171CCC96030 (Ethernet + RS‑485)

8. Safety & Handling

  • Installation/maintenance by qualified personnel per local codes.

  • Disconnect power before wiring/service to avoid electric shock.

  • Avoid water, moisture, corrosive substances, direct sunlight.

  • Use ESD protection to prevent static damage.

  • Do not open casing; no user‑serviceable parts inside.

9. Maintenance & Troubleshooting

  • Inspection: Quarterly check for cracks, loose screws, damaged connectors, LED status.

  • Cleaning: Dry, lint‑free cloth only; no solvents/abrasives.

  • Common Issues:

    • PWR Off: Check 5 V DC supply from I/O base.

    • FLT On: CPU fault; re‑seat adapter, reload program, check I/O base.

    • COMM No Response: Verify RS‑232 wiring, baud rate, parity, slave address.

    • No Program Execution: Ensure program downloaded, RUN mode active, no fatal faults.

10. Replacement Information

171CCS70010 is discontinued. Recommended replacements:
  • 171CCS76000: RS‑485 Modbus, 256 KB Flash, 0–60 °C

  • 171CCC96030: Ethernet + RS‑485, IEC 61131‑3 + LL984, 1 MB Flash