The 171CCC98020 is a high‑performance processor adapter for Schneider Electric Modicon Momentum I/O bases, turning them into standalone PLCs. It features a 50 MHz x86 CPU, 10/100 Mbps Ethernet (Modbus TCP), and an RS‑485 Modbus port. Only LL984 programming is supported (no IEC 61131‑3); it is discontinued, replaced by 171CCC98030 (adds IEC support, 1 MB Flash).

Description

1. General Description

The 171CCC98020 is a high‑performance processor adapter for Schneider Electric Modicon Momentum I/O bases, turning them into standalone PLCs. It features a 50 MHz x86 CPU, 10/100 Mbps Ethernet (Modbus TCP), and an RS‑485 Modbus port. Only LL984 programming is supported (no IEC 61131‑3); it is discontinued, replaced by 171CCC98030 (adds IEC support, 1 MB Flash).

2. Product Identification

  • Model: 171CCC98020

  • Manufacturer: Schneider Electric

  • Series: Modicon Momentum

  • Type: M1/M1E Processor Adapter (Ethernet + RS‑485 Modbus, 50 MHz)

  • Compatibility: All Modicon Momentum I/O bases (170XTS series)

  • Status: Discontinued (replaced by 171CCC98030)

  • Country of Origin: France

  • Certifications: CE, UL, cUL, FM Class 1 Div 2, NEMA 250

3. Technical Specifications

Processor & Memory

  • Processor: x86‑based, 50 MHz

  • Flash Memory: 512 kB

  • RAM: 544 kB

  • Program Memory: 18 kB (LL984 only)

  • Data Memory: 24 kB

  • Scan Time: 0.3 ms per kB

  • Word Length: 16‑bit

I/O Capacity

  • Discrete I/O: 8192 inputs / 8192 outputs

  • Register I/O: 26,048 words in / 26,048 words out

Communication Ports

  • Ethernet: 10/100 Mbps, Modbus TCP/IP (auto‑sensing)

  • RS‑485 Modbus: RTU/ASCII, master/slave, 19.2 kbps max

  • Diagnostics: LAN activity, link status, IP conflict, Modbus traffic

Electrical

  • Supply Voltage: 5 V DC ±5% (from Momentum I/O base)

  • Power Consumption: ≤ 15 W

Environmental

  • Operating Temperature: 0 °C to +40 °C

  • Storage Temperature: −40 °C to +85 °C

  • Humidity: 5–80% RH (non‑condensing)

  • Vibration: 0.75 mm displacement, 1 g acceleration

  • Shock: 15 g peak, 11 ms duration

  • Altitude: Up to 1000 m (no derating)

Physical

  • Dimensions (H × W × D): 25 mm × 125 mm × 183 mm

  • Weight: 0.09 kg (0.19 lbs)

  • Material: Lexan (industrial polycarbonate)

4. Key Features

  • Dual Communication: Ethernet (Modbus TCP) + RS‑485 (Modbus RTU)

  • LL984 Only: Optimized for legacy LL984 (no IEC 61131‑3)

  • Compact & Light: 0.09 kg, fits standard Momentum I/O bases

  • Diagnostic LEDs: PWR (green), RUN (green), FLT (red), LAN (yellow), MBUS (yellow)

  • Industrial Durability: 0–40 °C operation, shock/vibration resistant

5. Applications

  • Standalone PLC control with Momentum I/O bases

  • Distributed automation via Ethernet (Modbus TCP) and serial (RS‑485) networks

  • Retrofit projects using LL984 programming

  • OEM equipment needing compact PLCs with dual‑port communication

  • Machine control (material handling, packaging, textiles)

6. Installation Instructions

  1. Power Off: Disconnect power to the Momentum I/O base.

  2. ESD Protection: Use anti‑static wristband when handling the adapter.

  3. Mounting: Align 171CCC98020 with the I/O base connector; press firmly until seated. Tighten screws.

  4. Wiring:

    • Ethernet: Connect CAT5e/CAT6 to RJ45 port (10/100 Mbps auto‑sensing).

    • RS‑485: Connect 2‑wire shielded cable to Modbus terminals.

  5. Power Up: Apply 5 V DC. Check LEDs: PWR ON, RUN blinking (program execution), LAN/MBUS blinking (activity).

  6. IP Configuration: Use BootP Lite or EcoStruxure Control Expert to set IP, subnet, gateway.

  7. Programming: Download LL984 program via Modsoft, Concept, or ProWORX 32.

7. Compatibility

  • I/O Bases: All Modicon Momentum discrete/analog I/O bases (170XTS series)

  • Software: Modsoft ≥ V2.5, Concept ≥ V2.1, ProWORX 32/NxT (LL984 only)

  • Network: Modbus TCP/IP (Ethernet), Modbus RTU/ASCII (RS‑485)

8. Safety & Handling

  • Installation/maintenance only by qualified personnel per local codes.

  • Disconnect power before wiring/maintenance to avoid electric shock.

  • Avoid water, moisture, corrosive substances, direct sunlight.

  • Use ESD protection to prevent static damage.

  • Do not open casing; no user‑serviceable parts inside.

9. Maintenance & Troubleshooting

  • Inspection: Quarterly check for cracks, loose screws, damaged connectors.

  • Cleaning: Dry, lint‑free cloth only; no solvents.

  • Common Issues:

    • PWR Off: Check 5 V DC supply from I/O base.

    • FLT On: CPU fault; re‑seat adapter, reload program, check I/O base.

    • Ethernet Link Down: Verify cable, switch port, IP settings, BootP.

    • Modbus No Response: Check RS‑485 wiring, baud rate, slave address.

    • No Program Execution: Ensure LL984 program is downloaded and RUN mode active.

10. Replacement Information

171CCC98020 is discontinued. Direct replacement: 171CCC98030 (supports LL984 + IEC 61131‑3, 1 MB Flash, same ports/footprint, 0–60 °C operation)。