170MCI10001
May 23, 2026

170MCI10001

The 170MCI10001 is a factory‑assembled, shielded Interbus communication cable for Modicon Momentum and Quantum automation platforms. It provides a reliable, high‑speed link between Interbus‑compatible modules, supporting real‑time distributed I/O and peer‑to‑peer communication in industrial environments. The cable is pre‑tested and requires no field wiring, ensuring fast deployment and consistent performance.

Description

1. General Description

The 170MCI10001 is a factory‑assembled, shielded Interbus communication cable for Modicon Momentum and Quantum automation platforms. It provides a reliable, high‑speed link between Interbus‑compatible modules, supporting real‑time distributed I/O and peer‑to‑peer communication in industrial environments. The cable is pre‑tested and requires no field wiring, ensuring fast deployment and consistent performance.

2. Product Identification

  • Model Number: 170MCI10001

  • Manufacturer: Schneider Electric (Modicon)

  • Product Line: Modicon Momentum / Quantum

  • Protocol: Interbus (INTERBUS S)

  • Application: Interbus network trunk/drop, rack‑to‑rack module interconnection

  • Length: 1 m (3.28 ft / 100 cm)

  • Connectors: 2 × male low‑profile shielded D‑sub (Interbus pinout)

  • Cable Type: Shielded twisted pair (differential signaling)

  • Color: Black

  • Weight: Approximately 0.07 kg (0.15 lb / 74 g)

  • Warranty: 18 months

  • Country of Origin: Portugal (PT)

  • Status: Active (as of 2026)

3. Electrical and Mechanical Specifications

  • Interface: Low‑profile shielded D‑sub (Interbus pinout)

  • Wiring: Factory‑prewired; no user wiring required

  • Shielding: 100% foil + braid shield (EMI/RFI immunity)

  • Conductors: 2 twisted pairs (for Interbus differential signaling)

  • Insulation: Industrial PVC (black)

  • Minimum Bend Radius: ≥ 8 × cable diameter

  • Operating Temperature: 0 °C to +40 °C

  • Storage Temperature: 0 °C to +50 °C

  • Humidity: 5% to 80% RH (non‑condensing)

  • Altitude: Up to 1,000 m above sea level (no derating)

  • Protection Class: IP20

  • Certifications: CE, RoHS, UL, cUL, CSA; California Prop 65 (lead warning)

4. Compatibility

  • Platforms: Modicon Momentum (170 series), Quantum

  • Devices: Interbus communication adapters, Momentum/Quantum I/O modules with Interbus ports

  • Network Topologies: Interbus trunk/drop, linear, star (via hub)

  • Software: Unity Pro, Interbus Configurator

5. Key Features

  • Plug‑and‑play: Pre‑tested factory assembly enables immediate use

  • 1 m Length: Ideal for standard rack and panel layouts

  • Low‑Profile Shielded D‑Sub Connectors: Ensure robust, noise‑immune connections

  • Interbus‑Compliant: Supports full Interbus protocol speed and determinism

  • Hot‑Swap Compatible: Module replacement without network shutdown

  • High Noise Immunity: Double shielding for harsh industrial environments

6. Applications

  • Interbus module interconnections in Momentum/Quantum racks

  • Trunk/drop links for distributed I/O systems

  • Rack‑to‑rack communication in multi‑cabinet setups

  • Material handling, packaging, textile, and process control applications

  • High‑speed real‑time automation requiring deterministic data transfer

7. Installation Instructions

  1. Power Off: Disable power to all connected modules before installation.

  2. Align Connectors: Match the D‑sub connector key with the Interbus port on the first module.

  3. Insert Firmly: Push the connector until the screws can be easily tightened (hand‑tight only).

  4. Secure Connectors: Tighten the D‑sub screws to 0.5–0.8 N·m to ensure shield contact.

  5. Connect Second End: Repeat the process for the Interbus port on the second module.

  6. Verify Connection: Ensure both connectors are fully seated and secured.

  7. Power On: Restore system power and verify Interbus network status using PLC configuration software.

8. Maintenance

  • Quarterly Inspection: Check D‑sub connectors for wear, dirt, or bent pins.

  • Cable Care: Avoid heavy mechanical stress, sharp bends, or crushing.

  • Shield Integrity: Verify shield continuity; follow Interbus grounding rules (single‑end grounding recommended).

  • Replacement: Replace the cable if insulation is damaged or connectors show corrosion.

9. Safety Precautions

  • Qualified Personnel: Installation and service must be performed by qualified technical staff.

  • Power Disconnection: Always disconnect power before connecting or disconnecting the cable.

  • Indoor Use Only: Designed for indoor industrial environments; avoid direct sunlight and moisture.

  • Damage Check: Do not use the cable if insulation or connectors are damaged.

  • Disposal: Dispose of the cable in accordance with local electronic waste regulations.

10. Troubleshooting

No Interbus Communication

  • Confirm both D‑sub connectors are fully seated and screws are tightened.

  • Verify Interbus network power and termination (120 Ω resistors at trunk ends).

  • Check that module Interbus addresses are unique and correctly configured.

Intermittent Communication

  • Inspect for loose D‑sub screws or bent pins.

  • Check for excessive vibration or cable movement.

  • Ensure the shield is properly connected at both ends.


Get a Quote