170MCI04110
May 23, 2026

170MCI04110

The 170MCI04110 is a factory‑assembled, shielded Modbus Plus (MB+) / RS485 master communication cable for the Modicon Momentum automation platform. It provides a short, robust link between MB+ master ports on Momentum communication adapters and I/O bases, supporting high‑speed peer‑to‑peer and master‑slave communication in compact rack or panel layouts. The cable is pre‑tested and requires no field wiring, enabling fast, reliable deployment in space‑constrained industrial environments.

Description

1. General Description

The 170MCI04110 is a factory‑assembled, shielded Modbus Plus (MB+) / RS485 master communication cable for the Modicon Momentum automation platform. It provides a short, robust link between MB+ master ports on Momentum communication adapters and I/O bases, supporting high‑speed peer‑to‑peer and master‑slave communication in compact rack or panel layouts. The cable is pre‑tested and requires no field wiring, enabling fast, reliable deployment in space‑constrained industrial environments.

2. Product Identification

  • Model Number: 170MCI04110 (also referenced as 170‑MCI‑041‑10)

  • Manufacturer: Schneider Electric (Modicon)

  • Product Line: Modicon Momentum

  • Protocol: Modbus Plus (MB+) / RS485 (master)

  • Application: Master‑slave, short‑haul interconnection, compact rack clusters

  • Length: 0.3 m (0.98 ft / 1 ft)

  • Connectors: 2 × male shielded RJ45 (MB+ master pinout)

  • Cable Type: Shielded twisted pair (RS485 differential signaling)

  • Weight: Approximately 0.06 kg (0.13 lb)

  • Warranty: 2 years

  • Country of Origin: France

  • Status: Active (as of 2026)

3. Electrical and Mechanical Specifications

  • Interface: RJ45 (shielded, MB+ master pinout)

  • Wiring: Factory‑prewired; no user wiring required

  • Shielding: 100% foil + braid shield (EMI/RFI immunity)

  • Conductors: 2 twisted pairs (RS485 differential signaling)

  • Insulation: Industrial PVC (gray)

  • Minimum Bend Radius: ≥ 8 × cable diameter

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: -40 °C to +85 °C

  • Humidity: 5% to 80% (non‑condensing)

  • Altitude: Up to 1,000 m above sea level (no derating)

  • Protection Class: IP20

  • Certifications: CE, RoHS, UL, cUL, CSA

4. Compatibility

  • Platforms: Modicon Momentum (170 series), Premium, Quantum

  • Devices: MB+ master communication adapters (e.g., 170MCIxxx), Momentum I/O bases with integrated MB+ master ports

  • Network Topologies: MB+ master‑slave, short trunk/drop, compact rack cluster‑mode

  • Software: Unity Pro, MB+ Network Configurator

5. Key Features

  • Plug‑and‑play: Pre‑tested factory assembly for immediate use

  • 0.3 m Length: Optimized for tight, space‑saving installations

  • Shielded RJ45 Connectors: Industrial‑grade noise immunity

  • Master‑Mode Ready: Designed for MB+ master port interconnections

  • Hot‑Swap Compatible: Module replacement without network shutdown

  • 1 Mbps MB+ Support: Full deterministic communication speed

6. Applications

  • Short‑link MB+ master‑slave connections in Momentum racks

  • Compact panel and machine‑mounted I/O interconnections

  • Cluster‑mode master communication in limited‑space cabinets

  • High‑speed distributed I/O in material handling and packaging

  • Factory floor automation with tight layout constraints

7. Installation Instructions

  1. Power Off: Disable power to all connected modules before installation.

  2. Align Connectors: Match the male RJ45 key with the MB+ master port on the first module.

  3. Insert Firmly: Push until the latch clicks, confirming secure shield contact.

  4. Connect Second End: Repeat for the MB+ port on the second module.

  5. Verify Connection: Ensure both connectors are fully seated and locked.

  6. Power On: Restore power and verify MB+ network status via PLC software.

8. Maintenance

  • Quarterly Inspection: Check RJ45 connectors for wear, dirt, or bent pins.

  • Cable Care: Avoid heavy stress, sharp bends, or crushing.

  • Shield Integrity: Verify continuity; follow MB+ grounding rules (avoid both‑end grounding).

  • Replacement: Replace if insulation is damaged or connectors show corrosion.

9. Safety Precautions

  • Qualified Personnel: Installation and service by qualified technical staff only.

  • Power Disconnection: Always disconnect power before connecting/disconnecting.

  • Indoor Use Only: For indoor industrial environments; avoid sunlight and moisture.

  • Damage Check: Do not use if insulation or connectors are damaged.

  • Disposal: Dispose per local electronic waste regulations.

10. Troubleshooting

No MB+ Communication

  • Confirm both RJ45 latches are fully engaged.

  • Verify MB+ network power and termination (120 Ω at trunk ends).

  • Check unique MB+ addresses and correct master/slave configuration.

Intermittent Communication

  • Inspect for loose latches or bent pins.

  • Check for excessive vibration or cable movement.

  • Ensure proper shield connection at both ends.


Get a Quote