170MCI02080
May 23, 2026

170MCI02080

The 170MCI02080 is a 10-meter (30 ft), factory‑assembled, shielded Modbus Plus (MB+) / RS485 cable for Modicon Momentum IP20 T‑junction and long‑distance cluster‑mode communication. It extends MB+ network reach between racks or remote I/O bases, supporting 1 Mbps deterministic peer‑to‑peer and distributed I/O communication.

Description

1. General Description

The 170MCI02080 is a 10-meter (30 ft), factory‑assembled, shielded Modbus Plus (MB+) / RS485 cable for Modicon Momentum IP20 T‑junction and long‑distance cluster‑mode communication. It extends MB+ network reach between racks or remote I/O bases, supporting 1 Mbps deterministic peer‑to‑peer and distributed I/O communication.

2. Product Identification

  • Model Number: 170MCI02080 (also 170‑MCI‑020‑80)

  • Manufacturer: Schneider Electric (Modicon)

  • Product Line: Modicon Momentum

  • Protocol: Modbus Plus (MB+) / RS485

  • Application: IP20 T‑junction, long‑haul inter‑rack links

  • Length: 10 m (≈30 ft)

  • Connectors: 2 × male RJ45 (shielded, MB+ pinout)

  • Cable Type: Shielded twisted pair (RS485 differential)

  • Weight: ~1 lb (0.45 kg)

  • Warranty: 18 months

  • Country of Origin: USA

  • Status: Active (as of 2026)

3. Electrical & Mechanical Specifications

  • Interface: RJ45 (shielded, MB+ pinout)

  • Wiring: Factory‑prewired, no field wiring

  • Shielding: 100% foil + braid (EMI/RFI protection)

  • Conductors: 2 twisted pairs (RS485 signaling)

  • Insulation: Industrial PVC (gray)

  • Bend Radius: ≥ 10× cable diameter

  • Operating Temperature: 0 °C to +60 °C

  • Storage Temperature: -40 °C to +85 °C

  • Humidity: 5%–95% (non‑condensing)

  • Protection Class: IP20

  • Certifications: CE, RoHS, UL, cUL, CSA; California Prop 65

4. Compatibility

  • Platforms: Modicon Momentum (170 series), Premium, Quantum

  • Devices: MB+ adapters (170MCIxxx), Momentum I/O bases with MB+

  • Topologies: MB+ trunk/drop, IP20 T‑junction, inter‑rack links

  • Software: Unity Pro, MB+ Network Configurator

5. Key Features

  • 10 m length: Ideal for inter‑rack and long‑distance runs

  • Shielded RJ45: Industrial‑grade noise immunity

  • Plug‑and‑play: Pre‑tested, no wiring required

  • Hot‑swap compatible: Replace modules without network shutdown

  • MB+ 1 Mbps: Full deterministic performance at maximum length

  • Cluster‑mode ready: Connect multiple adapters across racks

6. Applications

  • Inter‑rack MB+ communication in large automation systems

  • IP20 T‑junction connections for extended MB+ networks

  • Remote I/O links between Momentum racks

  • High‑speed distributed I/O and peer‑to‑peer control

  • Factory floor and process control systems

7. Installation

  1. Power off all connected devices.

  2. Align RJ45 male connector with MB+ port on first module.

  3. Insert firmly until latch clicks (ensures shield contact).

  4. Repeat for second module’s MB+ port.

  5. Verify both connectors are fully seated and locked.

  6. Route cable with gentle bends; avoid sharp corners or crushing.

  7. Power on system; verify MB+ network status in PLC software.

  8. For T‑junction: Connect one end to trunk, other to drop module.

8. Maintenance

  • Inspect RJ45 connectors quarterly for wear, dirt, or bent pins.

  • Keep cable free of mechanical stress, sharp bends, or heavy loads.

  • Maintain shield integrity; follow MB+ grounding rules (single‑end ground).

  • Replace cable if insulation, shielding, or connectors are damaged.

9. Safety Notes

  • Installation/service only by qualified personnel.

  • Disconnect power before connecting/disconnecting the cable.

  • Indoor industrial use only; avoid direct sunlight, moisture, and chemicals.

  • Do not use if cable or connectors show damage.

  • Dispose of per local e‑waste regulations.

10. Troubleshooting

  • No MB+ communication:

    • Check both RJ45 connectors are fully latched.

    • Verify MB+ network power and termination (120 Ω at trunk ends).

    • Confirm unique MB+ addresses and correct network configuration.

  • Intermittent communication:

    • Inspect for loose latches, bent pins, or damaged shielding.

    • Check for excessive vibration or cable movement.

    • Verify proper shield grounding (single end only).


Get a Quote