170ADO73050
May 23, 2026

170ADO73050

The 170ADO73050 is a 230 VAC discrete output base for the Schneider Electric Modicon Momentum distributed I/O platform. It provides 8 solid‑state Triac outputs organized as 2 groups of 4 channels, designed to control 230 VAC actuators, relays, contactors, solenoids, and small motors in industrial and building automation. The module offers high‑voltage isolation, LED status indicators, and removable terminal blocks for easy installation and maintenance.

Description

1. General Description

The 170ADO73050 is a 230 VAC discrete output base for the Schneider Electric Modicon Momentum distributed I/O platform. It provides 8 solid‑state Triac outputs organized as 2 groups of 4 channels, designed to control 230 VAC actuators, relays, contactors, solenoids, and small motors in industrial and building automation. The module offers high‑voltage isolation, LED status indicators, and removable terminal blocks for easy installation and maintenance.

2. Product Identification

  • Model Number: 170ADO73050

  • Series: Modicon Momentum

  • Type: Discrete AC output base (Triac, 2×4 channels)

  • Channel Configuration: 8 outputs (230 VAC, 47–63 Hz)

  • Dimensions (W × D × H): 125 × 47.5 × 141.5 mm

  • Weight: 0.32 kg

  • Protection Class: IP20

  • Certifications: CE, UL, cUL, CSA, RoHS

  • Logic Type: Positive (true high)

  • Isolation (Field ↔ Bus): 1780 VAC for 1 minute

  • LED Indicators: 8 green LEDs (one per channel; on = active)


3. Electrical Specifications

Outputs (8 Channels, 230 VAC)

  • Rated Voltage: 230 VAC (195–253 VAC operating range, 47–63 Hz)

  • Output Type: Solid‑state (Triac)

  • Current Rating:

    • Per channel: 2 A (continuous)

    • Per group (4 channels): 8 A

    • Per module (8 channels): 16 A

  • Voltage Drop (On): ≤ 1.5 V @ 2 A

  • Leakage Current (Off): ≤ 2.5 mA @ 230 VAC

  • Minimum Load Current: 5 mA (per channel)

  • Response Time: 0.5 line cycle (0 → 1 or 1 → 0)

  • Surge Current:

    • 15 A for 1 cycle

    • 10 A for 2 cycles

    • 5 A for 3 cycles

  • Protection: Per‑group 5 A slow‑blow internal fuses (2 fuses total)

  • Inductive Loads: External RC snubber recommended for inductive loads > 100 mH

Power

  • Supply Voltage: 24 VDC ±20% (logic power)

  • Current Consumption: 150 mA @ 24 VDC (logic only)

  • Power Dissipation: 6 W typical, 7.5 W maximum (logic + full load)


4. Environmental Ratings

  • Operating Temperature: 0 °C to +60 °C (32 °F to 140 °F), non‑condensing

  • Storage Temperature: −40 °C to +85 °C, non‑condensing

  • Relative Humidity: 5% to 95%, non‑condensing

  • Vibration: IEC 60068‑2‑6 (1 g, 10–150 Hz)

  • Shock: IEC 60068‑2‑27 (15 g, 11 ms)

  • Altitude: Up to 5000 m (derate above 2000 m)

  • EMC: IEC 61000‑6‑2, IEC 61000‑6‑4 (industrial noise immunity)


5. Key Features

  • 8 Triac Outputs: 2×4 channels for 230 VAC control in compact footprint.

  • High Current Capacity: 2 A per channel, 16 A total for heavy‑load applications.

  • Grouped Protection: 5 A slow‑blow fuses per group for overload/short‑circuit safety.

  • High Isolation: 1780 VAC isolation between field and bus circuits for safety.

  • Fast Switching: 0.5 line‑cycle response for precise AC load control.

  • Removable Terminal Blocks: Simplify wiring and module replacement.

  • Snap‑On Mounting: Fast attachment to Momentum backplane.

  • LED Status: 8 green LEDs for immediate channel status visibility.


6. Compatibility

  • Backplane: Modicon Momentum I/O base rack.

  • Adapters: 170ENT (Ethernet), 170PBM (Profibus), 170CPS (power supply) series.

  • PLC Compatibility: Quantum, Premium, M340, Momentum controllers.

  • Terminals: 14–22 AWG copper wire, torque 0.5–0.6 N·m.


7. Applications

  • 230 VAC Actuators: Relays, contactors, solenoids, small AC motors (≤ 2 A).

  • Industrial Control: Conveyors, pumps, valves, heaters, lighting systems.

  • Building Automation: HVAC, fan control, access control, lighting systems.

  • High‑Cycle Loads: Triac design ideal for frequent AC switching (no mechanical wear).

  • Distributed I/O: Decentralized control in material handling, packaging, and machine tools.


8. Installation & Wiring

  1. Power Off: Disconnect all system power before installation.

  2. Mounting: Snap module firmly onto Momentum backplane; ensure proper grounding.

  3. Wiring (Outputs – Triac/230 VAC):

    • Connect line (L1) to module 1L+ terminal.

    • Connect neutral (N) to module 1N terminal.

    • Connect load between OUT terminal and neutral (N).

  4. Torque: Tighten terminals to 0.5–0.6 N·m (14–22 AWG copper wire).

  5. Verification: Check connections; power on and confirm LED status (green = active).


9. Maintenance

  • Periodic Inspection: Check terminal tightness and LED operation every 6 months.

  • Cleaning: Keep surface free of dust and contaminants; use dry cloth only.

  • Environment: Avoid corrosive gases, extreme vibration, or moisture.

  • Fuse Check: Inspect internal fuses annually; replace with 5 A slow‑blow fuses if blown.


10. Safety Notes

  • 230 VAC Hazard: Only qualified electricians should perform wiring; follow local electrical codes.

  • Voltage Limits: Do not exceed 253 VAC on outputs.

  • Current Ratings: Adhere to 2 A per channel / 16 A per module limits.

  • Isolation: Maintain 1780 VAC isolation between field and bus circuits.

  • Inductive Loads: Use external RC snubbers for inductive loads > 100 mH.

  • Disposal: Dispose of module per local electronic waste regulations.