170ADO54050
Description
1. General Description
2. Product Identification
Model Number: 170ADO54050
Series: Modicon Momentum
Type: Discrete AC output base (Triac, 2×8 channels)
Channel Configuration: 16 outputs (120 VAC, 47–63 Hz)
Dimensions (W × D × H): 125 × 47.5 × 141.5 mm
Weight: 0.284 kg
Protection Class: IP20
Certifications: CE, UL, cUL, CSA, FM Class 1 Division 2, RoHS
Logic Type: Positive (true high)
Isolation (Field ↔ Bus): 1780 VAC for 1 minute
LED Indicators: 16 green LEDs (one per channel; on = active)
3. Electrical Specifications
Outputs (16 Channels, 120 VAC)
Rated Voltage: 120 VAC (85–132 VAC operating range, 47–63 Hz)
Output Type: Solid‑state (Triac)
Current Rating:
Per channel: 1 A (continuous)
Per group (8 channels): 8 A
Per module (16 channels): 16 A
Voltage Drop (On): ≤ 1.5 V @ 0.5 A
Leakage Current (Off): ≤ 1.9 mA @ 120 VAC
Minimum Load Current: 5 mA (per channel)
Response Time: 0.5 line cycle (0 → 1 or 1 → 0)
Surge Current:
15 A for 1 cycle
10 A for 2 cycles
5 A for 3 cycles
Protection: Per‑group 5 A slow‑blow internal fuses (2 fuses total)
Inductive Loads: External RC snubber recommended for inductive loads > 100 mH
Power
Supply Voltage: 24 VDC ±20% (logic power)
Current Consumption: 125 mA @ 24 VDC (logic only)
Power Dissipation: 6 W typical, 7.5 W maximum (logic + full load)
4. Environmental Ratings
Operating Temperature: 0 °C to +60 °C (32 °F to 140 °F), non‑condensing
Storage Temperature: −40 °C to +85 °C, non‑condensing
Relative Humidity: 5% to 95%, non‑condensing
Vibration: IEC 60068‑2‑6 (1 g, 10–150 Hz)
Shock: IEC 60068‑2‑27 (15 g, 11 ms)
Altitude: Up to 5000 m (derate above 2000 m)
EMC: IEC 61000‑6‑2, IEC 61000‑6‑4 (industrial noise immunity)
5. Key Features
16 High‑Density Triac Outputs: 2×8 channels for 120 VAC control in compact footprint.
1 A Per Channel: Balanced current capacity for medium‑load AC devices.
Grouped Protection: 5 A slow‑blow fuses per group for overload/short‑circuit safety.
High Isolation: 1780 VAC isolation between field and bus circuits for safety.
Fast Switching: 0.5 line‑cycle response for precise AC load control.
Removable Terminal Blocks: Simplify wiring and module replacement.
Snap‑On Mounting: Fast attachment to Momentum backplane.
LED Status: 16 green LEDs for immediate channel status visibility.
6. Compatibility
Backplane: Modicon Momentum I/O base rack.
Adapters: 170ENT (Ethernet), 170PBM (Profibus), 170CPS (power supply) series.
PLC Compatibility: Quantum, Premium, M340, Momentum controllers.
Terminals: 14–22 AWG copper wire, torque 0.5–0.6 N·m.
Busbar Support: Optional busbar for 3/4‑wire field devices.
7. Applications
120 VAC Actuators: Relays, contactors, solenoids, small AC motors (≤ 1 A).
Industrial Control: Conveyors, pumps, valves, heaters, lighting systems.
Building Automation: HVAC, fan control, access control, lighting systems.
High‑Cycle Loads: Triac design ideal for frequent AC switching (no mechanical wear).
Distributed I/O: Decentralized control in material handling, packaging, and machine tools.
8. Installation & Wiring
Power Off: Disconnect all system power before installation.
Mounting: Snap module firmly onto Momentum backplane; ensure proper grounding.
Wiring (Outputs – Triac/120 VAC):
Connect line (L1) to module 1L+ and 2L+ terminals.
Connect neutral (N) to module 1N and 2N terminals.
Connect load between OUT terminal and neutral (N).
Torque: Tighten terminals to 0.5–0.6 N·m (14–22 AWG copper wire).
Verification: Check connections; power on and confirm LED status (green = active).
9. Maintenance
Periodic Inspection: Check terminal tightness and LED operation every 6 months.
Cleaning: Keep surface free of dust and contaminants; use dry cloth only.
Environment: Avoid corrosive gases, extreme vibration, or moisture.
Fuse Check: Inspect internal fuses annually; replace with 5 A slow‑blow fuses if blown.
10. Safety Notes
120 VAC Hazard: Only qualified electricians should perform wiring; follow local electrical codes.
Voltage Limits: Do not exceed 132 VAC on outputs.
Current Ratings: Adhere to 1 A per channel / 16 A per module limits.
Isolation: Maintain 1780 VAC isolation between field and bus circuits.
Inductive Loads: Use external RC snubbers for inductive loads > 100 mH.
Disposal: Dispose of module per local electronic waste regulations.