140XBP00200
May 23, 2026

140XBP00200

140XBP00200 is a 2‑slot backplane for the Schneider Electric Modicon Quantum PLC series. It provides physical mounting, high‑speed signal interconnection, and power distribution for up to 2 Quantum I/O or special‑function modules in a compact rack segment. Designed for local, distributed, or remote I/O applications, it serves as a building block for custom‑length racks and multi‑rack systems.

Description

1. Product Overview

140XBP00200 is a 2‑slot backplane for the Schneider Electric Modicon Quantum PLC series. It provides physical mounting, high‑speed signal interconnection, and power distribution for up to 2 Quantum I/O or special‑function modules in a compact rack segment. Designed for local, distributed, or remote I/O applications, it serves as a building block for custom‑length racks and multi‑rack systems.

2. Key Features

  • 2 module slots: accepts standard Quantum I/O, CPU, and bus modules

  • High‑speed parallel backplane: 32‑bit extension bus, 100 Mbps bandwidth

  • Integrated power distribution: +5 V logic, ±12 V I/O to modules

  • Compact footprint: enables small, cost‑effective I/O stations

  • Rack extension compatible: works with 140XBE expander modules for multi‑rack systems

  • Hot‑swap capable: modules can be inserted/removed under power

  • Robust industrial design: for high vibration and electrical noise environments

  • Certifications: CE, UL, cUL; RoHS compliant

3. Technical Specifications

General

  • Model: 140XBP00200

  • Type: 2‑slot backplane / rack segment

  • Slots: 2 (for standard Quantum modules)

  • Bus type: 32‑bit high‑speed extension bus

  • Bus current draw: 750 mA (from rack power supply)

  • Power rails: +5 V (logic), ±12 V (I/O)

  • Weight: approx. 0.23 kg

  • Mounting: standard Quantum rack or panel‑mounted kit

Environmental

  • Operating temperature: 0 °C to +60 °C

  • Storage temperature: −40 °C to +85 °C

  • Humidity: 10–80 % RH, non‑condensing

  • Altitude: ≤1,000 m (no derating)

  • Protection class: IP20 (front)

  • Vibration: 10–150 Hz, 0.15 mm amplitude (IEC 60068‑2‑6)

  • Shock: 15 g, 11 ms half‑sine (IEC 60068‑2‑27)

Mechanical

  • Dimensions (W×H×D): 40.34 × 250 × 103.85 mm

  • Material: metal chassis with fiberglass‑reinforced PCB

  • Connector: high‑density edge connector (module interface)

4. LED Indicators (on Modules, not Backplane)

  • PWR (Green): module power OK

  • RUN (Green): module active, communicating

  • FAULT (Red): module or backplane fault

  • LINK (Yellow): backplane data activity

5. Installation & Wiring

Rack Installation

  1. Align the 140XBP00200 with the Quantum rack mounting rails.

  2. Slide into position and secure with screws (torque per manufacturer specs).

  3. Insert I/O modules into the two slots until latched.

  4. For multi‑rack systems, connect backplane cables between 140XBP segments and 140XBE expanders.

Power & Grounding

  • Power: supplied via rack power supply (no direct user wiring to backplane)

  • Ground: connect backplane chassis to system earth ground

  • Cable routing: separate signal and power cables; shielded cables recommended for high‑noise areas

6. Configuration (Unity Pro)

  1. Open Unity Pro V7.0 or later.

  2. In hardware configuration, add a 2‑slot rack and assign 140XBP00200 as the backplane.

  3. Insert appropriate I/O modules into slots 1 and 2.

  4. Configure I/O addresses, diagnostics, and fault handling.

  5. Download configuration to CPU; backplane initializes automatically.

7. Operation & Diagnostics

Normal Operation

  • All module PWR/RUN LEDs ON; FAULT OFF

  • Backplane provides stable power and communication to both slots

Fault Conditions

  • Module FAULT ON: Check module seating, backplane connector, or module failure

  • No module PWR: Verify rack power supply and backplane voltage rails

  • Communication errors: Inspect backplane cables, expanders, and grounding

Diagnostic Data

  • Backplane voltage status (+5 V, ±12 V)

  • Module presence/absence flags

  • Bus communication quality metrics

8. Maintenance

  • Monthly: Inspect module seating, LEDs, and cable connections

  • Quarterly: Check mounting screw torque; clean backplane connectors (compressed air only)

  • Semi‑annually: Verify ground continuity and shield integrity

  • Replacement: Replace backplane if connectors are damaged or corrosion is present

9. Safety & Compliance

  • Qualified personnel only for installation, wiring, and maintenance.

  • Disconnect all power before servicing the backplane or modules.

  • For industrial control systems only; not for direct life‑safety applications without additional safety layers.

  • Follow local electrical codes and EMC installation guidelines.

10. Compatibility

  • Quantum CPUs: 140CPU65150, 140CPU67160, 140CPU68060, 140CPU69060 and later

  • Expander modules: 140XBE10000, 140XBE10000C

  • I/O modules: all standard Quantum digital/analog I/O, safety, and specialty modules

  • Racks: compatible with Quantum 12/14/16‑slot rack systems


Get a Quote