140NRP95401C
Description
1. Product Overview
Coated version: Acrylic conformal coating for dust, moisture, vibration, and corrosive atmospheres.
Fiber type: Single‑mode (9/125 µm) with LC duplex connectors.
Long distance: Up to 16 km at 1 Mbps.
2. Key Features
Single‑mode fiber: 1300 nm wavelength, long‑haul transmission.
Dual redundant fiber channels: 2×LC single‑mode ports + 1×BNC coaxial port.
Max distance: 16,000 m (9/125 µm single‑mode).
Conformal coating: Harsh environment protection.
Optical isolation: Eliminates ground loops and EMI.
Hot‑swappable: Replace without system shutdown.
Diagnostic LEDs + relay: Real‑time status and fault alarming.
Certifications: CE, UL 508, CSA C22.2 No.142, FM Class 1 Div 2, RoHS.
3. Technical Specifications
Electrical
Bus current: 750 mA @ 5 V DC
Power consumption: 5 W
Inrush current: 1.8 A @ 5 V DC
Data rate: 1.544 Mbps (Manchester encoded RIO data)
Bit error rate: 10⁻⁹ over dynamic range
Optical (Single‑Mode, 1300 nm LED)
| Fiber Type | Max Distance | Tx Power | Attenuation Range |
|---|---|---|---|
| 9/125 µm (SM) | 16,000 m | 0.45 dBm | −15 to −8 dB |
Receiver sensitivity: −25 dBm
Dynamic range: 20 dB
Detected silence: −45 dBm
Rise/fall time: 20 ns
Environmental
Operating temp: 0 °C to +60 °C
Storage temp: −40 °C to +85 °C
Humidity: 5–95 % (non‑condensing)
Altitude: Up to 2,000 m
Coating: Conformal acrylic (harsh environment)
Mechanical
Dimensions (W×H×D): 40.34 × 250 × 103.85 mm
Weight: 0.554 kg
Material: Polycarbonate (PC) + conformal coating
4. LED Indicators & Diagnostic Relay
LED Status (Same as 140NRP95400C)
| LED | Color | State | Meaning |
|---|---|---|---|
| READY | Green | Off | No power / internal fault |
| On | Powered & operational | ||
| COM ACT | Green | Off | No coaxial activity |
| Flashing | Coaxial data transfer | ||
| OPT FAULT | Red | Off | Optical link OK |
| On | Optical link failure | ||
| ERR | Red | Off | Module healthy |
| On | Internal fault / config error |
Diagnostic Relay
Normal: Energized (contacts closed)
Fault: De‑energized (contacts open) – triggers on power loss, module failure, or optical fault
5. Installation
5.1 Rack Mounting
Ensure Quantum rack power is OFF (or hot‑swap in powered rack).
Align module with rack slots, insert firmly until seated.
Secure with rack latch.
5.2 Cable Connections
Fiber Ports (LC Duplex, Single‑Mode)
Tx → Rx of remote module; Rx → Tx of remote module.
Cable: 9/125 µm single‑mode fiber.
Min bend radius: 10× cable diameter.
Coaxial Port (BNC)
Cable: 75 Ω (RG‑6 or equivalent).
Max length: 100 m (copper segment).
5.3 Harsh Environment Notes
Conformal coating protects against condensation, dust, and mild corrosives; do not immerse or expose to direct liquid spray.
6. Configuration
No manual configuration: Auto‑detects RIO S908 network.
Software: Unity Pro V7.0+; add to I/O list, download project.
Topologies: Point‑to‑point, dual redundant, multidrop (up to 31 drops).
7. Operation & Maintenance
Normal Operation
READY: Green ON
COM ACT: Green flashing
OPT FAULT: Red OFF
ERR: Red OFF
Troubleshooting
OPT FAULT ON:
Check Tx/Rx reversal, dirty/damaged LC connectors, tight bends, or wrong fiber type (must be single‑mode 9/125 µm).
ERR ON:
Re‑seat module, check 5 V backplane power, replace module if fault persists.
READY OFF:
Verify rack power, check backplane short circuits.
Maintenance
Quarterly: Inspect and clean LC connectors (isopropyl alcohol).
Semi‑annually: Test diagnostic relay.
Firmware: Update via Unity Pro (check Schneider Electric website).
8. Safety
Qualified personnel only for installation/service.
Disconnect power before rack maintenance.
Laser safety: Class 1 LED (1300 nm) – no eye hazard under normal use.
9. Ordering & Compatibility
140NRP95401C: Coated single‑mode, LC duplex connectors.
140NRP95400C: Coated multimode, ST connectors.
140NRP95400: Non‑coated multimode, ST connectors.
10. Support
Manufacturer: Schneider Electric
Documentation: EIO0000000872 (PDF)
Get a Quote