140ERT85420
May 23, 2026

140ERT85420

Model: 140ERT85420 Brand: Schneider Electric Series: Modicon Quantum Type: 32‑point Digital Input Module with High‑Resolution SOE (Sequence of Events) & Time Stamp Application: Power, metallurgy, process industries; requires precise event sequencing and fault tracing

Description

1. General Information

  • Model: 140ERT85420

  • Brand: Schneider Electric

  • Series: Modicon Quantum

  • Type: 32‑point Digital Input Module with High‑Resolution SOE (Sequence of Events) & Time Stamp

  • Application: Power, metallurgy, process industries; requires precise event sequencing and fault tracing


2. Key Features

  • 32 isolated DC inputs (2 groups × 16 points)

  • 1 ms SOE time resolution (vs. 10 ms for 140ERT85410)

  • High‑accuracy time synchronization: IRIG‑B (primary), DCF77 (backup)

  • Time stamp precision: ≤1 ms with IRIG‑B; ≤10 ms with DCF77

  • Input voltage: 24–125 VDC

  • Sink/source configurable per group

  • Opto‑isolated: 1500 VAC isolation (channel‑to‑channel, channel‑to‑backplane)

  • Local event buffer: retains events during communication loss


3. Technical Specifications

Input

  • Channels: 32

  • Voltage range: 24–125 VDC

  • On‑state current: 8 mA typical

  • Off‑state current: ≤1 mA

  • Response time: 10 ms (standard); 1 ms (SOE mode)

  • Isolation: 2 groups (16 points each), 1500 VAC dielectric strength

Time & SOE

  • Event resolution: 1 ms

  • Time sync: IRIG‑B (1 pulse/sec), DCF77 (1 pulse/min)

  • Time stamp accuracy: ±1 ms (IRIG‑B)

  • Clock drift: ≤10 ppm (internal oscillator)

Power & Mechanical

  • Backplane power: 5 VDC, 350 mA max

  • Power consumption: ≤1.75 W

  • Operating temperature: 0 °C to +60 °C

  • Storage temperature: −25 °C to +70 °C

  • Humidity: 5–95 % non‑condensing

  • Protection: IP20

  • Size: Standard Quantum single slot (100 × 40 × 250 mm)

  • Weight: ≈0.45 kg


4. Front‑Panel LEDs

  • PWR (Green): On = Backplane power OK

  • RUN (Green): Blinking = Module active, communicating with CPU

  • F (Red): On = Hardware/configuration fault; Blinking = Time sync loss

  • IN0–IN31 (Green): On = Input channel active


5. Wiring & Installation

  • Terminals: Screw‑type, 0.5–2.5 mm² wire size

  • Isolated groups: Two independent 24–125 VDC supplies

  • Installation: Standard Quantum backplane slot; hot‑swap capable


6. Compatibility

  • CPU: Quantum 140CPUxxx series

  • Software: Unity Pro v5.0+ / EcoStruxure Control Expert

  • Accessories: Quantum backplanes, terminal blocks, power supplies


7. Differences from 140ERT85410

  • 140ERT85420: 1 ms SOE resolution, IRIG‑B sync, higher precision

  • 140ERT85410: 10 ms SOE resolution, DCF77 primary, lower cost