140EDK77100
Description
1. General Information
Model: 140EDK77100
Brand: Schneider Electric
Series: Modicon Quantum
Type: Ethernet Development Kit / Communication Interface Module
Function: Ethernet-based programming, configuration, and diagnostic interface for Quantum PLC systems; supports custom communication application development.
2. Product Overview
3. Technical Specifications
3.1 Physical & Environmental
Mounting: Quantum backplane (single slot), hot-swappable
Dimensions (W×H×D): 103.9 × 40.3 × 250 mm
Weight: ~0.3 kg
Operating Temperature: 0°C to +60°C
Storage Temperature: -40°C to +85°C
Relative Humidity: 5%–95% (non-condensing)
Certifications: CE, UL, CSA, ATEX, RoHS
3.2 Communication Interfaces
Ethernet Port: 10/100 Mbps TCP/IP (RJ45)
Serial Port: RS-232/RS-485 (via programming port, for debug)
Protocols Supported: Modbus TCP/IP, HTTP, BOOTP/DHCP, SNMP v2
3.3 Electrical
Power Supply: 5 V DC via backplane (no external power needed)
Power Dissipation: ≤ 6 W
Isolation Voltage: 2500 V AC (communication-to-backplane)
3.4 LED Indicators
PWR: Power status (green = normal)
LINK: Ethernet link (green = connected)
ACT: Ethernet activity (flashing = data transfer)
ERR: Fault alarm (red = error)
4. Key Features
Ethernet Development Platform: Enables custom TCP/IP application design for Quantum PLCs.
Embedded Web Server: Supports remote configuration, diagnostics, and data monitoring via browser.
Hot-Swappable: Replace module without system shutdown.
Multi-Protocol Support: Modbus TCP/IP, HTTP, BOOTP/DHCP, SNMP v2 for flexible network integration.
Diagnostic Tools: Real-time Ethernet statistics, fault logging, and remote I/O status monitoring.
5. Compatibility
Hardware: All Modicon Quantum racks, CPUs (140CPUxxx), and I/O modules.
Software: EcoStruxure Control Expert (Unity Pro) v7.0+.
Accessories: Standard RJ45 Ethernet cable, Quantum backplane, terminal blocks.
6. Installation Instructions
Power Off System: Ensure Quantum rack power is disconnected.
Insert Module: Align 140EDK77100 with an empty slot on the Quantum backplane; push firmly until seated.
Secure Module: Tighten front panel screws (if equipped).
Connect Ethernet Cable: Plug RJ45 cable into the module’s Ethernet port; connect the other end to a switch or PC.
Power On System: Restore power to the Quantum rack; verify PWR LED is green.
7. Configuration Steps
Open EcoStruxure Control Expert: Create or open a Quantum project.
Add Module: In the hardware configuration, insert 140EDK77100 into the correct slot.
Set IP Address:
Use BOOTP/DHCP for dynamic assignment, or
Configure static IP via software (default: 192.168.0.1).
Enable Protocols: Activate Modbus TCP/IP, HTTP, or SNMP as required.
Download Configuration: Transfer settings to the PLC; verify LINK and ACT LEDs function normally.
8. Applications
Custom Ethernet communication development for industrial automation.
Material handling, packaging, and textile machinery (high-speed data exchange).
Remote monitoring and control of Quantum PLC systems via Ethernet.
Integration of Quantum PLCs with SCADA/MES systems using Modbus TCP/IP.
9. Troubleshooting
PWR LED Off: Check backplane power supply; re-seat the module.
LINK LED Off: Verify Ethernet cable connection; check switch/port status.
ERR LED On: Check configuration (IP conflict, protocol error); re-download settings.
No Communication: Ensure firewall settings allow port 502 (Modbus TCP); verify network subnet matches.
10. Reference Documentation
Official Manual: Quantum Ethernet Development Kit (140EDK77100) User Guide
Document No.: 840 USE 116 00 (similar to NOE771xx series)
Software Manual: EcoStruxure Control Expert (Unity Pro) Configuration Guide
Get a Quote