330930-060-00-00
Description
I. Model Positioning
330930: Extension cable for NSv series
060: Total cable length 6.0 meters
00: No stainless steel armor protection layer
00: No explosion-proof compliance certification
Usage: General factory areas of steam turbines, compressors, and ordinary buildings. Used for signal transmission of shaft vibration and rotational speed key signals. Prohibited for use in flammable and explosive sites.
II. Core Parameters
1. Mechanical Structure
Overall length: 6.0 meters
Outer structure: Ordinary insulating sheath, no metal armor
Connection end: Both ends standard ClickLoc quick connectors, sealed and dust-proof
Minimum bending radius: Not less than 25mm
The cable is lightweight and suitable for regular line laying
2. Electrical Characteristics
Compatible system: 3300 XL NSv eddy current sensing system
Standard impedance: 50Ω
Frequency response range: 0~10kHz
Low signal loss, capable of resisting common electromagnetic interference, ensuring stable transmission
3. Environmental Tolerance
Working temperature: -40℃~+125℃
Protection level: IP67
Anti-vibration strength: 10g (10~1000Hz)
Suitable for ordinary non-hazardous conditions, not applicable to explosion-proof areas
4. System Adaptation
Adaptable probes: 330980 series high-temperature phase probes, conventional NSv detection probes
Adaptable preamplifiers: 330980-50-00, 330980-70-00
Adaptable systems: 3300 TSI, 3500 TSI monitoring racks
Adaptable modules: 3500/40M vibration module, 3500/50E rotational phase module
III. Installation Tips
1. The total length of the cable must be strictly matched. The length of the probe cable plus the extension cable should be consistent with the rated parameters of the preamplifier.
2. Keep the connectors clean. Avoid oil and dust from entering. Put on the protective cap when not in use.
3. Fix the wiring in sections, keep away from high-temperature and high-pressure pipelines, and strictly avoid hard bending and pulling.
4. Shielded wires are only grounded on one side of the preamplifier to prevent current circulation from interfering with the signal.
IV. Comparison of the Same Specification Models
330930-060-00-00: No armor, no explosion-proof, suitable for general ordinary conditions
330930-060-01-00: With armor protection, wear-resistant and durable, not for explosion-proof environments
330930-060-01-05: Armor combined with explosion-proof certification, can be used in hazardous areas
V. Common Faults
Signal disconnection: Check the connection plug status and the condition of the cable outer skin damage or breakage
Abnormal data fluctuation: Verify the grounding method, keep the line away from high-power electrical equipment
Measurement deviation: Check if the total length of the entire cable meets the calibration requirements of the preamplifier
Get a Quote