330930-065-00-00
Description
I. Model Positioning
330930: Extension cable for NSv series
065: Total cable length 6.5 meters
00: Without stainless steel armor protection
00: Without explosion-proof qualification certification
Usage: For normal non-hazardous conditions of steam turbines and compressors, combined with sensors to complete signal transmission of shaft vibration and rotational speed key signals
II. Core Parameters
1. Mechanical Structure
Overall length: 6.5m
Outer layer structure: Ordinary insulating sheath, without metal armor
Connection end: Both ends standard ClickLoc quick connectors, sealed dust-proof
Minimum bending radius: Not less than 25mm
Overall lightweight, suitable for regular wiring layout
2. Electrical Characteristics
Compatible system: 3300 XL NSv eddy current sensing system
Standard impedance: 50Ω
Frequency response range: 0~10kHz
Low signal loss, resistant to common electromagnetic interference, ensuring stable data transmission
3. Environmental Tolerance
Working temperature: -40℃~+125℃
Protection level: IP67
Anti-vibration strength: 10g (10~1000Hz)
Applicable scenarios: Ordinary factory areas, not suitable for flammable and explosive hazardous sites
4. System Adaptation
Adapted probes: 330980 series high-temperature phase key probes, conventional NSv detection probes
Adapted preamplifiers: 330980-50-00, 330980-70-00
Adapted systems: 3300 TSI, 3500 TSI monitoring racks
Adapted modules: 3500/40M vibration module, 3500/50E rotational key phase module
III. Installation Tips
1. Length ratio strictly follows the total length of the probe cable plus the extension cable, consistent with the rated length of the preamplifier
2. Avoid oil stains and dust on the connectors, wear a protective cap during idle periods
3. Segment the cables for fixation, keep away from high-temperature and high-pressure pipelines, avoid hard bending and pulling
4. Shield layer is only grounded on one side of the preamplifier, avoiding circulating interference signals
IV. Comparison of Same Specifications Models
330930-065-00-00: Without armor and explosion-proof, for normal ordinary conditions
330930-065-01-00: With armor protection, wear-resistant and durable, not for explosion-proof environments
330930-065-05-05: Armor with explosion-proof certification, suitable for hazardous areas
V. Common Faults
Signal interruption: Check the firmness of connector insertion, damage or breakage of cable outer skin
Value fluctuation: Check the grounding method, keep away from high-power electrical equipment
Transmission anomaly: Verify if the total length of the entire cable matches the parameters of the preamplifier
Get a Quote