330930-065-01-00
Description
I. Model Breakdown
330930: 3300 XL NSv Series Extension Cable
065: Length 6.5 m (21.3 ft)
01: Stainless steel armor + FEP outer sheath (oil-resistant, temperature-resistant, wear-resistant)
00: No explosion-proof certification (not for hazardous areas)
II. Core Parameters
1. Mechanical and Structural
Length: 6.5 m
Structure: Inner insulation → Shielding layer → Stainless steel armor → FEP outer sheath
Joints: Both ends ClickLoc® coaxial quick connectors, waterproof and dustproof
Minimum bending radius: ≥ 25 mm
Weight: Approximately 1.0 kg
2. Electrical Characteristics
Compatible system: 3300 XL NSv eddy current sensor
Impedance: 50 Ω
Frequency response: 0–10 kHz
Transmission characteristics: Low loss, anti-interference, suitable for long-distance signal transmission
3. Environmental Conditions
Operating temperature: -40°C ~ +125°C (FEP + armor can withstand)
Protection level: IP67
Explosion-proof: No certification (00), for non-explosion-proof areas
Anti-vibration: 10 g (10–1000 Hz)
III. System Compatibility (Must be Matched as a Set)
Probe: 330901-00-00 (1.0 m internal cable, NSv standard probe)
Preamplifier: 330980-50-00 / 330980-70-00 (Total length should = probe length + cable length)
Example: 1.0 m (probe) + 6.5 m (cable) = 7.5 m (preamplifier order length)
Monitoring Rack: 3300 TSI, 3500 TSI
Monitoring Module: 3500/40M (vibration), 3500/50M (phase / speed)
IV. Key Models in the Same Series (6.5m) Table
Model Length Armor + FEP Explosion-proof Certification Applicable Scenarios
330930-065-01-00 6.5m ✅ ❌ General industrial environment
330930-065-05-05 6.5m ✅ ✅ Explosion-proof / Hazardous areas
330930-065-00-00 6.5m ❌ ❌ Ordinary, short-life scenarios
V. Installation Points
Length must match precisely: probe length + extension cable length = nominal length of the preamplifier; otherwise, non-linearity and inaccurate measurement will occur.
Joint protection: avoid oil and dust; cover with protective cap after installation.
Cable routing fixation: fix every 0.5–1m, away from high-temperature/high-pressure pipelines; avoid hard bending.
Grounding: only single-ended grounding of the shielding layer on the preamplifier side is required to prevent circulating interference.