330-980-71-05
Description
I. Model Positioning
330980: High-temperature dedicated phase / speed probe (not ordinary shaft vibration probe)
71: Structural Configuration = With Built-in Cable + Side-Out Type (NSv)
05: Built-in Cable Length 5 meters
Usage: Gas turbine, steam turbine high-temperature casing / exhaust end, only for phase detection + speed measurement, not for shaft vibration / displacement.
II. Core Parameters (330980-71-05)
1. Mechanical Structure
Probe Type: Electromagnetic Vibration, High-Temperature Phase Detection Specialized
Installation Thread: 3/8 - 24 UNF (Standard)
Cable Type: Built-in 5-meter cable, no need to add extension cable
Shell Material: High-temperature resistant stainless steel (resistant to 175°C, vibration resistance 10g)
Protection Grade: IP67 (dustproof, oilproof, waterproof)
Outgoing Line Method: Side-Out (NSv, narrow type)
2. Electrical Characteristics
Measurement Principle: High-frequency Electromagnetic Vibration (Non-contact)
Adapter Compatibility: 330180 (Standard), 330181 (High Temperature)
Sensitivity: 7.87 V/mm (200 mV/mil)
Frequency Response: 0 - 10 kHz (covers 1 - 99999 rpm)
Trigger Pulse: Steep edge, no lost pulse, no noise (high phase accuracy)
Input Voltage: –24 VDC (±10%)
3. Environmental Tolerance (Key)
Probe Temperature: –40°C ~ +175°C (High Temperature Grade)
Cable Temperature: –40°C ~ +125°C
Vibration Resistance: 10 g (10 - 1000 Hz)
Temperature Drift: <0.5%/°C (Signal Stable at High Temperature)
4. System Adaptation
Adaptable Rack: 3500 TSI, 3300 TSI
Adaptable Module: 3500/50E, 3500/50M (Speed / Phase)
Total Cable Length: Built-in 5 meters, cannot be cut
III. Installation Tips (Consistent with 330980-X0-00)
1. Installation Gap
Recommended Gap: 1.0 - 1.5 mm (Phase Detection Tooth Top / Groove)
Target Surface: 4140 Steel, Area ≥ 3 times the probe diameter
Side / Back Clearance: ≥ 5 mm (Prevent Metal Interference)
2. Wiring (Three-wire System, Adapter → Probe)
Core Wire: Signal (+)
Inner Shield: Common (–)
Outer Shield: Ground (Single-ended Ground, Ground on Adapter Side)
3. Installation Steps
Clean Installation Holes and Measured Surface (No Oil Stain, No Bumps)
Manual Insert the Probe to a Slight Contact, Then Retreat 1.25 mm
Lock the Anti-Slip Nut (Torque 8 - 10 N·m)
Fix the Cable (Avoid Twisting, Bend Radius ≥ 25 mm)
IV. Differences from 330980-X0-00
71-05: With 5-meter Built-in Cable, Directly Connect to Adapter on Site
X0-00: No Built-in Cable, Must be Paired with 330130 Extension Cable
Other Parameters (Temperature Resistance, Sensitivity, Adaptable Module) Are Exactly the Same
V. Complementary List
Probe: 330980-71-05 (Built-in 5-meter Cable)
Adapter: 330180 (Standard) / 330181 (High Temperature)
Monitoring Module: 3500/50E (Recommended) / 3500/50M
Get a Quote