36363-XX
Description
I. Model Code (36363 - XX)
36363: Radiation Tolerant Preamplifier Series
XX: Version / Specification (such as -01, -02), usually corresponding to different certifications or interfaces
Common complete model: 36363 - 01, 36363 - 02
II. Core Parameters
1. Electrical
Power Supply: -24 VDC (±10%), 12 mA maximum
Output: Gap Voltage (proportional to probe -axis gap)
Sensitivity: 8 V/mm (200 mV/mil, standard)
Frequency Response: 0 – 10 kHz
Linear Range: 0.25 – 2.25 mm (8 mm probe)
Output Impedance: 50 Ω
2. Mechanical
Size: Approximately 144 × 88 × 100 mm
Weight: Approximately 0.9 kg
Installation: Panel / Rail Installation
Protection: IP54 (Front Panel)
3. Environment (Radiation Tolerant Core)
Operating Temperature: -40°C to +85°C
Radiation Tolerance: 1×10⁶ rad (γ rays), suitable for nuclear power plant reactor areas
Anti-Vibration: 10 g (10 – 1000 Hz)
4. Probe Compatibility (Radiation-Specific)
0.300" (7.6 mm): 330280 Matching Probe
0.420" (10.7 mm): 23268 Matching Probe
III. Key Features
Strong Radiation Compatibility: Specifically designed for high-radiation scenarios such as nuclear power plants, ordinary 3300 XL preamplifiers cannot replace it.
Long-term Stability: Signal drift is extremely small in radiation environments, with high long-term reliability.
System Compatibility: Can be directly connected to 3300/3500 TSI systems, no additional adaptation required.
Complete Replacement: The new model 330280 has the same functions / parameters / interfaces as the current main model.
IV. Supply and Replacement
36363 - XX: Out of Production, Only Available in Secondhand / Repaired Market
Direct Replacement: 330280 - 01 (Radiation-Tolerant Preamplifier, Factory Production)
Get a Quote