7203954-01
Description
I. Model Analysis
7203954: Original factory material code (order number) for 3500/42M module
‑01: Standard version (standard temperature range, standard firmware, no special customization)
Alias: 3500/42M (commonly used market model name)
II. Product Positioning and Usage
Function: Receives 4 channels of eddy current / magnetic sensor signals, each channel can be independently configured, capable of monitoring:
Radial vibration (shaft vibration)
Axial displacement (thrust)
Differential expansion (temperature difference)
Offset, acceleration, speed, etc.
Output: 4‑20mA analog output + alarm / dangerous relay, supports software configuration of alarm values.
Application: Key rotating machinery TSI systems such as steam turbines, gas turbines, compressors, fans, etc.
Companion: Compatible with 3300XL/7200 series probes (e.g., 330104, 72072‑01).
III. Core Technical Parameters
Channels: 4 channels (can be grouped in pairs, dual-function parallel)
Input: Eddy current / speed / acceleration sensors, -10 to +10VDC
Accuracy: ±0.2% FS (full scale)
Resolution: 0.366μA/bit
Power consumption: 7.7W (‑24VDC power supply)
Operating temperature: -40℃ to +85℃
Structure: Full-height card, 3500/05 rack installation, supports hot swapping
Configuration: 3500 rack software programming, independent alarms for channels (warning / danger)
IV. Comparison with 7200 Series (Upgrade Points)
Table
Item 7203954-01 (3500/42M) 72052-01 (7200 dual displacement card)
Number of channels 4 channels (multifunctional) 2 channels (only displacement)
Configuration Software flexible configuration, multiple parameters Hardware jumpers, fixed functions
Output 4‑20mA + relay Only relay
Compatibility Compatible with 3300/7200 probes Only 7200 probes
Status Active mainstream Outdated and discontinued
V. Alternatives and Compatibility
Direct replacement: 3500/42M (7203954-01), new / second-hand available.
Downward compatibility: Can directly replace old 72052-01, 72059-01R, etc., requires reconfiguration.
Upgrade suggestion: Upgrade the old 7200 system, prioritize **3500/42M + 3500/53 (overspeed)** combination.
Get a Quote